Installation Of Remote Condenser Unit; Location - Hoshizaki KML-700MRJZ Instruction Manual

Low-profile modular crescent cuber
Hide thumbs Also See for KML-700MRJZ:
Table of Contents

Advertisement

G. Installation of Remote Condenser Unit
• Installation of remote condenser unit must be performed by properly trained and
EPA-certified service personnel.
• The remote condenser unit must be installed in accordance with applicable
national, state, and local codes and regulations.
• Failure to install the remote condenser unit within these guidelines may adversely
affect safety, performance, component life, and warranty coverage.
• Power supply and ground wire to the remote condenser unit are supplied from the
icemaker. For details, see section "II.G.6. Electrical Connection."

1. Location

• The remote condenser unit is intended for outdoor use. Normal operating ambient
temperature must be within -20°F to +122°F (-29°C to +50°C). Operation of the
remote condenser unit, for extended periods, outside of this normal temperature
range may affect icemaker performance.
• The maximum line length for the standard line sizes and refrigerant charge is
66 feet (20 m). With larger line sizes and/or additional refrigerant, the maximum
line length is 100 feet (30.5 m). For details, see "II.G.4 Line Set Size and
Refrigerant Charge."
• The maximum vertical distance between the remote condenser unit and the
icemaker is 33 feet (10 m) above or 10 feet (3 m) below the icemaker. These
distances are measured fitting to fitting. See Fig. 9.
The remote condenser unit must be positioned in a permanent site under the following
guidelines:
• A firm and flat site.
• A dry and well ventilated area with 24" (61 cm) clearance at front and rear for proper air
circulation and ease of maintenance and/or service should they be required. See Fig. 10.
Max.
33'
(10 m)
Icemaker
Service Loop
Remote
Condenser
Unit
Max.
10'
(3 m)
Fig. 9
WARNING
NOTICE
Icemaker
Service Loop
Remote
Condenser
Unit
22
Min. 24" (61 cm) Clearance
Air
Air
Fig. 10