Optional Alphanumeric (1)

1
When this option appears in the template string, the data validator accepts an alphanumeric character if present.
Optional characters are not allowed as the first character(s) in a field of like characters.
Template
Valid data
99991
1234A
Optional Alpha (2)
When this option appears in the template string, the data validator accepts an alpha character if present. Optional
characters are not allowed as the first character(s) in a field of like characters.
Template
Valid data
AAAA2
ABCDE

Alpha or Digit (3)

3
The data validator requires an alphanumeric character in this position to validate the incoming data.
Template
Valid data
33333
12ABC
Valid data
Invalid data
12345
1234<
Valid data
Invalid data
WXYZ
ABCD6
Valid data
Invalid data
WXY34
12AB<