Memory Map - Sharp UP-600 Service Manual

Sharp up-600 cash register service manual
Hide thumbs Also See for UP-600:
Table of Contents

Advertisement

Signal
No.
CPU
I/O
name
30
IOWB
/MWE
31
SMEMRB
SMEMRB
32
SMEMWB
SMEMWB
33
RSTDRV
RSTDRV
34
AEN
/CS3
35
IOCHRDY
/WAIT
36
SD0
LD0
I/O
37
SD1
LD1
I/O
38
SD2
LD2
I/O
39
SD3
LD3
I/O
40
SD4
LD4
I/O
41
SD5
LD5
I/O
42
SD6
LD6
I/O
43
SD7
LD7
I/O
44
GND
GND
45
TPOUT+
TPOUT+
46
TPOUT-
TPOUT-
47
VDD
+5V
48
TX-
TX-
49
TX+
TX+
50
X1
X1
51
X2
X2
52
GND
GND
53
CD-
CD-
54
CD+
CD+
55
RX-
RX-
56
RX+
RX+
57
VDD
+5V
58
TPN-
TPIN-
59
TPN+
TPIN+
60
LEDBNC
LEDBNC
61
LED0
LED0
62
LED1
LED1
63
LED2
LED2
64
AUI
AUI
65
JP
JP
66
PNP
PNP
67
BS0
BS0
68
BS1
BS1
69
BS2
BS2
70
VDD
+5V
71
BS3
BS3
72
BS4
BS4
73
BA15
BA15
74
PL0
PL0
75
BCSB
BCSB
76
EECS
EECS
77
PL1
PL1
78
IRQS0
IRQS0
79
IRQS1
IRQS1
80
IRQS2
IRQS2
81
IOS0
IOS0
82
IOS1
IOS1
83
GND
GND
84
IOS2
IOS2
85
IOS3
IOS3
86
GND
GND
87
SD15
SD15
I/O
88
SD14
SD14
I/O
89
VDD
+5V
90
SD13
SD13
I/O
91
SD12
SD12
I/O
92
SD11
SD11
I/O
Remarks
I
Memory Write
I
N.U. (Pull-Up)
I
N.U. (Pull-Up)
I
Hardware Reset
I
Chip Select
O
Wait to CPU
DATA Bus
O
10Base-T output +
O
10Base-T output -
O
N.U. (Pull-Down)
O
N.U. (Pull-Down)
I
Oscillator connection terminal
O
Oscillator connection terminal
I
N.U. (OPEN)
I
N.U. (OPEN)
I
N.U. (OPEN)
I
N.U. (OPEN)
I
10Base-T input -
I
10Base-T input +
O
N.U. (OPEN)
O
N.U. (OPEN)
O
N.U. (OPEN)
O
N.U. (OPEN)
I
GND
I
Pull-Up
I
OPEN
I
OPEN
I
OPEN
I
OPEN
I
OPEN
I
OPEN
O
N.U. (OPEN)
I
OPEN
O
N.U. (OPEN)
O
N.U. (OPEN)
I
OPEN
I
OPEN
I
OPEN
I
OPEN
I
OPEN
I
OPEN
I
OPEN
I
OPEN
N.U. (Pull-Down)
N.U. (Pull-Down)
N.U. (Pull-Down)
N.U. (Pull-Down)
N.U. (Pull-Down)
Signal
No.
CPU
name
93
SD10
SD10
94
SD9
SD9
95
SD8
SD8
96
SLOT16
SLOT16
97
INT7
INT7
98
INT6
INT6
99
INT5
INT5
100
INT4
INT4
Note: Signals suffixed with the letter "B" are active in low level.

5. MEMORY MAP

H'00000000
Flash
H'0007FFFF
H'00400000
SRAM
H'00407FFF
H'00800000
Dual-Port SRAM
H'00800FFF
H'00C00000
H'00C*****
LAN Controller
H'01000000
DRAMS space
H'02000000
Reserved
H'FFFF8000
Built-in peripheral
Module
H'FFFF8800
Reserved
H'FFFFF000
Built-in RAM
H'FFFFFFFF
I/O
Remarks
I/O
N.U. (Pull-Down)
I/O
N.U. (Pull-Down)
I/O
N.U. (Pull-Down)
I
Pull-Down
O
N.U. (Pull-Down)
O
N.U. (Pull-Down)
O
N.U. (Pull-Down)
O
N.U. (Pull-Down)
CS0 SPACE
1 The CS0 space is a physical
of 4 MB. It uses LA0~LA16
alone and thus LAP AROUND
occurs.
In addition, the data bus size is
set to 8 bits using the operation
mode setting terminal of the CPU.
CS1 SPACE
2 The CS1 space is a physical
space of 4 MB. Is uses LA0~LA14
alone and thus LAP AROUND
occurs.
The data bus size is 8 bits.
CS2 SPACE
3 The CS2 space is a physical
space of 4 MB. It uses LA0~LA11
alone and thus LAP
AROUND occurs.
The data bus size is 8 bits.
CS3 SPACE
4 The CS3 space is a physical
space of 4 MB. Is uses LA0~LA19
alone and thus LAP AROUND
occurs.
The data bus size of the LAN
controller is fixed to 8 bits.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Up-700Dp-750

Table of Contents