8.5 TOUCH PANEL ADJUSTMENT

[How to adjust]
Perform the adjustment on the calibration test mode.
A
[How to activate the calibration test mode]
When the reset start is done while pushing SOURCE and OPEN/CLOSE, it shifts to the touch panel adjustment mode.
[Menu types in the mode]
The calibration test mode consists of the following menus.
Top menu
B
[Description of the top menu]
[Operation specification]
Operational
description
Menu enter
Selection cursor
up movement
Selection cursor
down movement
Select the menu desired to be adjusted using the up/down key (
C
Note 1) Calibration menu can be selected only when adjustment of the outermost circumference has been completed normally.
[Display specification]
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
1
2
3
4
5
6
7
8
D
9
10
11
12
13
Conditions for lighting of the adjustment complete mark "
Outermost circumference inspection :
16 points adjustment :
Calibration check
E
Conditions for the adjustment complete mark "
Outermost circumference inspection :
16 points adjustment :
Calibration check
F
92
1
2
Outermost circumference inspection
16 points adjustment
Coordinate inspection
Calibration verification
Data initialization
Remote
controller
key
MENU_ENTER
Adjustment completed mark
<
C A L I B R A T I O N
*
1 .
S e t
T P
*
[ U P ,
D O W N ]
:
C u r s o r
[ A . M E N U
]
:
M e n u
[ A C C
O F F
]
:
E n d
In case the outermost circumference inspection has been completed normally.
In case the calibration has been completed normally.
When line calibration check is completed properly.
In case the outermost circumference inspection has never been performed.
In case the EEPROM initialization has been performed.
In case the adjustment value has been initialized.
In case the 16 points adjustment has never been performed.
In case the EEPROM initialization has been performed.
In case the adjustment value has been initialized.
When line calibration check has never been executed or when calibration check ended with NG or was aborted.
When EEPROM is initialized.
When adjustment value is initialized (Factory Calibration Init is executed) from Data initialize menu.
AVH-P5150DVD/XN/RC
2
3
, ), then press ENTER key to enter into the selected menu.
Flicker initialized state
T E S T
>
F L I C K E R : O K
E E P R O M
: O K
3 C
m o v e m e n t
s e l e c t i o n
o f
t e s t
Operational specifications are displayed
".
" to go out
3
4
4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avh-p5150dvd/xn/rdAvh-p5150dvd/xn/riAvh-p5150dvd

Table of Contents