If Con Self Diagnostic Function - Sony DVP-F11 Service Manual

Cd/dvd player
Hide thumbs Also See for DVP-F11:
Table of Contents

Advertisement

6-10. IF CON SELF DIAGNOSTIC FUNCTION

1. FRONT BOARD TEST MODE
The front board test mode is the IF CON self diagnostic mode.
The IF CON can diagnose the functions of the front panel boards
that the IF CON controls. Normally, the IF CON makes a serial
communication with the SYSTEM CONTROL and operates fol-
lowing thecommands from the SYSTEM CONTROL, but in the
Test mode, the IF CON operates independently from the SYS-
TEM CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remocon receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Direct search dial function
5. Click shuttle function
6. Fluorescent display tube lighting check
Grid check
Anode check
7. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that monitors +3.3 V (PCONT) of MB-85 board is
not provided.
2. The monitoring timer for serial communication with the SYS-
TEM CONTROL is not provided. The set is not placed in the
Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the com-
mands from SYSTEM CONTROL)
2. HOW TO ENTER THE TEST MODE
The set must be placed in the Standby mode (red LED lights up).
In the standby mode, press the
key on the remocon while pressing the
so that the set enters the test mode.
When the Test mode becomes active, the automatic display se-
quence of the FL display tube starts.
1. LEDs and FL display tube all light up for about 5 seconds.
2. Then, the prototypical model name is displayed.
(This model name is a typical name of the series. As the but-
ton arrangement varies depending on the model, make sure
the difference.)
Display
DPX-1290
DVP-F11
3. Last updating date of the program is displayed.
Example: 981211
4. Following the "GRID TEST" display, odd grids and even grids
are blinking alternately (3 times).
5. Following the "ANODE TEST" display, even anodes and odd
anodes are blinking alternately (3 times). For the FL display
tube type A, even and odd numeric parts of music calendar are
blinking alternately (3 times).
6. All light-up mode restores.
Steps 1 through 6 are repeated. (Refer to "FLD Auto Test Opera-
tion" on page 6-12)
3. HOW TO EXIT FROM THE TEST MODE
[POWER]
Press the
buttons on the set and Remocon, and the FL
display tube turns off and the Standby mode is restored where
only the red POWER LED lights up. This is the case where the
SYSTEM CONTROL and IF CON are communicating normally.
To forcibly activate the Standby mode, press the
[STOP]
ton together with the
6-11
[RETURN]
key, then the
[STOP]
button on the set,
Model
[POWER]
button.
[SET UP]
but-

Advertisement