CHAPTER 5
III. PROBLEM, CAUSE AND CORRECTIVE ACTION
CanoScan 8000F may have the following five problems.
* Power LED not lighting
* Communication failure
* Scanning unit movement failure
* Poor image quality
* Acoustic noise
A. Power LED Not Lighting
Possible Cause
AC adapter is unplugged
from the outlet
AC Adapter cable is
disconnected from the scanner
AC adapter output voltage
failure
Button PCB failure
Main PCB failure
Main PCB connection failure
B. Communication Failure
Possible Cause
USB cable connection failure
Scanner communication failure
Scanning unit failure
5 - 4
Related Parts
None
None
AC Adapter
Button PCB
Main PCB
None
Table 5-1
Related Parts
USB cable
Main PCB
Scanning unit
Table 5-2
COPYRIGHT
2002 CANON INC. CANOSCAN 8000F REV.0 OCT. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
Check Method
Corrective Action
Plug the AC adapter into
Visual check
the outlet
Connect the AC adapter cable
Visual check
to the power connector on the
scanner
Replace the AC adapter
Output voltage
(+12V) check
Replace the button PCB
Tester check
Replace the main PCB
Tester check
(+12V, GND)
Properly connect the main PCB
Visual check
Corrective Action
Check Method
Visual check
Connect the USB cable
properly
Replace the main PCB
Trial replacement
Replace the scanning unit
Trial replacement