Installing UltraKey Lite with MAXPRO-Net
Step 3A: Configure the Controller for a Serial Port Connection
62
3.
Enter the IP address and Port Number of the MAXPRO-Net server under MAXPRO
Device Network Setting.
4.
Under Serial Port Setting, select a Baud Rate from the drop-down list. Options are
9600 or 19200 bps.
5.
Select a Connect Mode from the drop-down list. Options are 232 or 422.
6.
From the Joystick speed drop-down list, select Normal or High.
7.
Click Apply to save the configuration, Cancel to exit without saving or Default to
restore all factory default values.
Figure 4-14
MAXPRO Configuration Tab
Checking the Network Connection Using the Ping Function
After the IP address is entered and applied, press the Ping button.
A green Ping button indicates the device at this IP address has replied to the ping.
A red Ping button indicates the device at the IP address did not reply. Please check
that the IP address is correct and that there is a valid network path between the two IP
addresses.
1.
From the side menu, click Serial Port Configuration. See
2.
Under Serial Port1 Settings, select the following from each drop-down list as
required:
Baud Rate: 9600 or 19200 bps
Parity: none, even or odd
Stop Bits: 1 or 2 bits
Data Bits: 7 or 8 bits
Serial Mode: RS232, RS422 or RS485
3.
If required, repeat
step 2
for Serial Port2 Settings.