Honeywell MAXPRO-Net Commissioning Manual page 111

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

Equipment
Polling – Failed
Macro
Cold Boot
Macro
Warm Boot
Macro
Rev. B
Special Parameters
The MAXPRO-Net Server can poll various types of equipment in the
video system. Click on the Equipment Polling – Fail Macro: tab to select
the type of equipment that is polled and the macro sequence that
executes when that equipment fails to respond to a poll message.
Please refer to the MACRO GUIDE for more details on the macro
functionality.
Types of equipment that can be polled are:
Subracks
High Level Interfaces / Mimic Panels
Keyboards
Network nodes
Click on a field to toggle the selected equipment polling status. Enter the
desired macro in the Equipment Fail Macro field you want the system to
execute when an equipment type fails.
Click on the OK button when the desired equipment settings are
selected. To exit the Equipment Setting dialog box without making
changes, click on the Cancel button.
When the MAXPRO-Net Server is powered up or reset, the COLD BOOT
macro sequence will be executed following all normal system and
equipment initialization.
Please refer to the MACRO GUIDE in the Operator's Manual for more
details on the macro functionality.
Enter the desired macro in the field and press Enter on the keyboard.
Note: Cold Boot can be initiated from setmax (Toolbar button).
When the MAXPRO-Net Server receives a reset command the WARM
BOOT macro sequence will be executed following all normal system and
equipment initialization.
Please refer to the MACRO GUIDE in the Operator's Manual for more
details on the macro functionality.
Enter the desired macro in the field and press Enter on the keyboard.
Note: Warm Boot can be initiated from setmax (Toolbar button).
6-49
HMXMC001013
31-Mar-06