Honeywell MAXPRO-Net Commissioning Manual page 194

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

Source Control -
Control Slot
Source Control -
Control Site
Pretext - Pretext
Subrack ID
Pretext - Pretext
Slot Number
Video Fail Slot
Rev. B
Video Inputs
This represents the PIT to which the camera is connected.
Should be greater than zero. Valid range: 1 to 4. For input
numbers 1- 256, the Control slot value is 1, for 257-512, the slot
value is 2, for 513 – 768, slot value is 3 and for 769 – 1026, the slot
value is 4.
This represents the camera number of the video input channel.
Valid range: 1 to 255.
This represents the 'V'+ communication port number to which
Videoblox MVT (Multi Channel Video Titler) is connected. Valid
range: 'V' + maximum communication ports.
This represents the physical input slot for the Videoblox analog
video input channel in MVT. Valid range: 1 to 4096. For pretext
slot numbers 1 to 16, MVT address is 1, for 17 to 32 – MVT
address is 2, so on.
The slot value 1 represents video fail detection for this input is
enabled. Slot value 0 represents video fail detection is disabled
for this input.
8-6
HMXMC001013