Honeywell MAXPRO-Net Commissioning Manual page 101

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

Network Alarm
Alarm Start Macro
Alarm Finish Macro
Rev. B
When the current alarm input is actually connected to another MAXPRO-Net
system within a network configuration, the NETWORK ALARM field is used
to specify the exact location and reference for the alarm input device.
e.g.
#03:A1234
LINK
For more details, please refer to the NETWORKING section of the user's
guide.
Enter the location and reference for the alarm input (if applicable) and press
Enter on the keyboard.
When an alarm condition is detected for an alarm input, the ALARM START
MACRO is executed. This can be used to perform automatic system control
functions.
Please refer to the MACRO GUIDE for more details on the macro
functionality.
Enter the desired macro number in the field and press Enter on the
keyboard.
When a detected alarm input returns to its normal state, the ALARM FINISH
MACRO is executed.
Please refer to the MACRO GUIDE for more details on the macro
functionality.
Enter the desired macro number and press Enter on the keyboard.
External Alarm Inputs
- the actual alarm input resides on network node 3
and is defined on node 3 as alarm 1234.
- signifies that status changes of the current alarm
input will be broadcast on the network.
6-39
HMXMC001013
31-Mar-06