Honeywell MAXPRO-Net Commissioning Manual page 103

Crosspoint matrix video switching system
Hide thumbs Also See for MAXPRO-Net:
Table of Contents

Advertisement

Subrack Slot
Remote Camera
Number
Output Bit
Network Auxiliary
Output
Rev. B
Auxiliary Control Outputs
This field defines the slot number within the control subrack where the
control output module resides. Valid slot numbers are 1 – 32 for I/O and
combination video/I/O subracks, and 1 for HD Series subracks.
Enter the slot number and press Enter on the keyboard.
For VideoBlox Subrack, this represents the physical control input slot
number from AVBPIT alarm concentrator. Valid range: 1 to 255.
If the control output is located at a remote PTZ site, then the camera number
of that remote PTZ must be specified. Entering data in this field will clear the
Subrack ID and Subrack Slot fields. Valid camera numbers are 1 – 9999.
This field should be set to zero (0) when a control output module in a
subrack is used.
Enter the camera number (if applicable) or 0 in the field and press Enter on
the keyboard.
Note: This field is not applicable for VideoBlox subracks
Selecting this field brings up a dialog box, which allows configuration of the
separate output circuit (called output bits) being used.
Click on the check box (to the left of an output bit) to toggle its state. If the
box to the left of the output bit contains a check mark, the bit is controlled by
the Auxiliary Control Output. Each control output defined in SetMax can
control 1 or more output bits. Click on the "Select All" button in the dialog
box for all 8 output bits to be controlled by a single Auxiliary Control Output.
When the current auxiliary control output is actually connected to another
MAXPRO-Net system within a network configuration, the NETWORK
AUXILIARY OUTPUT field is used to specify the exact location and reference
for the Auxiliary Control Output.
e.g.
#03:X1234
LINK
For more details, please refer to the NETWORKING section of the user's
guide.
If applicable, enter the network location, and press Enter on the keyboard.
- the actual output resides on network node 3 and is
defined there as control output 1234.
- signifies that status changes of the current control
output will be broadcast on the network.
6-41
HMXMC001013
31-Mar-06