Advertisement

Installing or Replacing Server Components

Replacing Power Supplies

The server can have one or two power supplies. When two power supplies are installed they are
redundant as 1+1.
The power supplies must both be either 450W or 650W; do not mix power supply types.
Note
See
LEDs and Buttons, page 3-4
To replace or install a power supply, follow these steps:
If you have ordered a server with power supply redundancy (two power supplies), you do not have to
Note
power off the server to replace power supplies because they are redundant as 1+1.
Remove the power supply that you are replacing or a blank panel from an empty bay (see
Step 1
a.
b.
c.
d.
Install a new power supply:
Step 2
a.
b.
c.
d.
Figure 3-27
1
Cisco UCS C24 Server Installation and Service Guide
3-52
Power Specifications, page A-2
for information about the power supply LEDs.
Perform one of the following actions:
If your server has only one power supply, shut down and power off the server as described in
the
"Shutting Down and Powering Off the Server" section on page
If your server has two power supplies, you do not have to shut down the server.
Remove the power cord from the power supply that you are replacing.
Grasp the power supply handle while pinching the release lever towards the handle.
Pull the power supply out of the bay.
Grasp the power supply handle and insert the new power supply into the empty bay.
Push the power supply into the bay until the release lever locks.
Connect the power cord to the new power supply.
If you shut down the server, press the Power button to return the server to main power mode.
Removing and Replacing Power Supplies
PSU 2
PSU 1
1
2
Power supply handle
for more information about the power supplies. See
PCIe 4
PCIe 3
PCIe 5
Power supply release lever
2
Chapter 3
Maintaining the Server
Rear Panel
Figure
3-27):
3-6.
PCIe 1
PCIe 2
OL-26647-01

Advertisement

Table of Contents
loading

Table of Contents