Wohler AMP2-SDA/AVU User Manual page 10

2u digital audio speaker monitor
Table of Contents

Advertisement

AMP2-SDA/AVU and AMP2-SDA/APP User Manual P/N 821576 Rev-A
10
Balance Control
This control changes the volume balance between the left and right speaker channels. Note that this control attenuates the
signal from the source, so that the left and right bass frequencies (summed together and reproduced in the woofer channel)
will respond to balance adjustments in tandem with the left and right speaker channels. See page 16 for more information
concerning the balance control characteristics.
11
AES Signal Status LED
This bi-color (GREEN/RED) LED (AES) glows GREEN as long as a valid AES/EBU digital datastream is being received. It
glows RED to indicate errors. By setting a rear panel DIP switch, two types of error detection are available:
Reception Errors: errors in reception of data or no data stream at all.
Reception and Data Errors: errors in reception and data errors identified by the sending device (possibly invalid).
See the AES Termination and Error Type DIP Switch (Item C, page 12) for information about setting the error type.
12
SDI Signal Status LED
This bi-color (GREEN/RED) LED (SDI) glows GREEN as long as a valid SDI digital datastream is being received. It glows
RED if TSR errors are present in the signal. If there is no SDI signal present the LED will be unlit. This LED functions
whether or not the SDI digital signal is selected for monitoring through the unit.
10
Front Panel Features
(Continued)
© 2004 Wohler Technologies Inc. ALL rights reserved