Troubleshooting - WAGNER GM 2600 0179070 Owner's Manual

Air assisted/airless sprayer gun
Table of Contents

Advertisement

Available languages

Available languages

Cleaning/Changing the Filter
1. Remove the high pressure hose from the material inlet
fitting.
2. Holding the material tube at the wrench flats with one
wrench, unscrew the material inlet fitting another wrench.
3. Pull out the cylindrical filter.
4. Rinse the filter in a cleaning solvent or exchange with a
new filter.
5. Push the cone end of the new or cleaned filter into the
into the material tube.
6. Make sure the spring is in position in the material inlet
fitting.
7. Holding the material tube at the wrench flats with one
wrench, thread the material inlet fitting into the material
tube. Tighten securely.
8. Reattach the high pressure hose to the material inlet
fitting.
Material Tube
Material Inlet Fitting
High-Pressure Hose
Problem
Insufficient material supply.
Poor spraying pattern.
Leaking air valve.
© Wagner. All rights reserved.
Filter
Spring

Troubleshooting

Cause
1. Material pressure set too low.
2. Blocked spray gun filter or pump high
pressure filter.
3. Tip is blocked.
4. Tip is too small.
1. Tip is too large.
2. Material pressure at the pump is set too
low.
3. Material viscosity is too high.
4. Atomizing air is set incorrectly.
1. Damaged air valve seal.
NOTE: Make sure the correct filter is being used for
the tip and material being used (refer to the
"Gun Filter Chart" below and the "AirCoat Tip
Chart" in the Accessories section).
Gun Filter Chart
Part
For Tip Sizes
Number
0034383 (1 pc.)
0.007" – 0.011"
0089960 (2 pc.)
0089324 (1 pc.)
0.013" – 0.015"
0089959 (2 pc.)
0034377 (1 pc.)
0.018" – 0.036"
0089958 (2 pc.)
Solution
1. Increase the material pressure at pump.
2. Clean or replace the gun filter and/or pump
high pressure filter.
3. Clean the tip (refer to the tip cleaner in the
Accessories section).
4. Select a larger tip (refer to the AirCoat Tip
Chart in the Accessories section).
1. Select a smaller tip (refer to the AirCoat Tip
Chart in the Accessories section).
2. Increase the material pressure at the pump.
3. Dilute the material according to the material
manufacturer's instructions.
4. Adjust the atomizing air using the gun air
adjustment knob or pressure regulator at
the compressor.
1. Replace the air valve seal (refer to the
"Repairing Air Valve Seals" procedure in the
Maintenance section).
5
Filter
Color of
Mesh
Filter
Body
180
red
100
yellow
50
white
English
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents