Omega DP116-RTD User Manual page 32

Miniature panel thermometer
Table of Contents

Advertisement

DISPLAY
Type:..........................................................................................7-segment, LED
Height: .......................................................................................0.56" (14.2 mm)
Symbols:..................................................................................................-1.8.8.8
Overrange Indication:....................................Three least-significant digits blank
Colors: .........................................................................................Red - standard
DIGITAL INPUTS
Hold:......................................................................TTL or 5V CMOS compatible
ENVIRONMENTAL
Operating Temperature: ...............................................0¡ to 60¡C(32¡ to 140¡F)
Storage Temperature: .............................................-40¡ to 85¡C (-40¡ to 185¡F)
Relative Humidity: ..............................................95% at 40¡C (non-condensing)
MECHANICAL DIMENSIONS
Bezel: .......................................................................0.94" x 2.83" (24 x 72 mm)
Depth Behind the Bezel: .....................................4.72" (120 mm) w/ connectors
Panel Cutout: .................................................0.87"H x 2.68" W (22.2 x 68 mm)
Weight: .............................................................................7 ounces (200 grams)
Panel Thickness .........................................................minimum: 0.03" (0.76mm)
Case Material: ......................................................94V-1 UL-rated thermoplastic
POWER
AC Frequency: ......................................................................................50/60 Hz
Max. Power: .................................................................................2.4 watts max.
AC Voltage: ................................................................115Vac ±15% 25mA max.
DC Voltage:..........................................................................9-26 Vdc @ 110mA
External Fuse Protection needed:...................................32mA, 115Vac/230Vac
UL Slow-blow (per single unit)
Installation Category: .................................................................. I per EN61010
Equipment Class: .........................................................................I per EN61010
Pollution Degree: ........................................................................2 per EN61010
Refer to the Glossary in Section 6.
maximum: 0.25" (6.25mm)
230Vac ±15% 14mA max.
100Vac ±15% 30mA max.
24Vac ±15% 127mA max.
24
Green - optional
40mA, 100Vac
160mA, 24Vac
125mA, 9-26Vdc