  • Page 1 TALKING EAR AND FOREHEAD THERMOMETER INSTRUCTION MANUAL MODEL: DX6635 Please read this manual before use 0197...
  • Page 3: Safety Precautions

    - Thank you for purchasing our DX6635 Talking Multi-Functional Ear and Forehead thermometer For a desirable use of this product, be sure to read this user anual before battery case and gently pull out th hermometer will not activate - For safe and proper use of this product, be sure to read and fuIly understand...
  • Page 4 Measurement should be suspended until the ear has adjusted to room temperature.
  • Page 6 1st of the manufacturing year...
  • Page 8 3. Press and hold [ T ] button for 2 seconds to toggle the language which you want or non talking function.
  • Page 11 MAINTENANCE, STORAGE AND CALIBRATION Maintenance: 1. Remove any stains on the body with a soft and dry cloth. 2. Don't wash with water or detergent containing abrasive or benzene. Storage: 1. Clean the thermometer and cover to protect the lens after each use. 2.
  • Page 12 SPECIFICATION Product Name: Talking Multi-Functional Ear and Forehead thermometer Model: DX6635 Power supply: DC3V (2 x AAA battery) Power consumption: <30mA (for voice prompt) Temperature sensing Part: IR sensor Measuring range: 32.0℃ ~ 42.9℃ (89.6℉ ~109.3℉) Room Temperature: 5.0℃ ~ 59.9℃ (41.0℉ ~139.8℉) Measuring accuracy: +/- 0.2℃...
  • Page 13 SYMBOLS Attention: Read the operating nstructions for use ! Applied part of type B Disposal in accordance with Directive 2002/96/EC (WEEE) Complies with the European Medical Device Directive (93/42/EEC) and amended by directive 2007/47/EC 0197 requirements. Notified body TÜV Rheinland (CE0197) Batch code Serial number The name and the address of the manufacturer...
  • Page 14 GUIDANCE AND MAUFACTU ER'S DECLARATION Guidance and manufacturer's declaration - electromagnetic emissions The device is intended for use in the electromagnetic environment specified below. The customer or the user assures that it is used in such an environment. Emissions test Compliance Electromagnetic environment - guidance The device must emit electromagnetic e RF emissions...
  • Page 15 Guidance and manufacturer's declaration — electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment. Electromagnetic IEC 60601 Immunity test Compliance level environment - guidance test level Floors should be wood,...
  • Page 16 Guidance and- manufacturer's declaration. Electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user should assure that it is used in such an environment. Portable and mobile RF Communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the...
  • Page 17 assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, should be observed to verify normal operation.
  • Page 18: Declaration Of Conformity

    Present the Warranty Card with seal of distribution center (incI. name and address) for repair free. DECLARATION OF CONFORMITY Shenzhen Dongdixin Technology Co., LTD declares that the DX6635 complies with following normative documents: IEC60601-1, IEC60601-1-2, IEC60601-1-4, ASTM E1965-98, ISO10993-5, ISO10993-10, ISO10993-1,ISO 14971,EN 12470-5.
  • Page 20 2) Dispose with care, please consult the retailer for details. Distributed by: Omega Medical Instruments Pty Ltd Suite 8, Level 12 101 Bathurst Street NSW 2000 AUSTRALIA Manufacturer: Name: Shenzhen Dongdixin Technology Co., LTD.