Calibration Mode - NCI 7815 User Manual

Parcel bench scale
Hide thumbs Also See for 7815:
Table of Contents

Advertisement

Calibration Mode

Calibration (CAL) Mode
Calibrating your
scale requires a
certified test weight
to ensure accurate
weighing.
Step-by-Step
Instructions for CAL
Mode
To abort the CAL
Mode at any time,
press the SW-1 switch.
14
The calibration (CAL) mode menu lets you
calibrate your scale. The items in the calibration
menu are as follows:
POUNDS/KILOGRAMS – Select the unit of
measure (lb or kg).
SCALE or CLASS – Select the scale rounding
factor as a SCALE or as a CLASS (Weight
Classifer) rounding device.
SCALE = .5 division rounding.
CLASS = .9 division rounding.
Factory default setting is CLASS.
CAPACITY – Select the capacity / resolution of
the scale (150.05 or 150.1).
Follow these steps to calibrate your scale. Refer
to Figure 2.
1. From the normal weighing mode, press SW-
1...
2. Press the ZERO key until...
3. Press the TEST key to start calibration...
4. If you want to change the unit of measure,
press the ZERO key to toggle between LB
and KILO. When the choice you want is
displayed, press the TEST key...
Model 7815 Parcel Bench Scale User's Manual
DIAG is displayed.
CAL is displayed.
LB is displayed.
The current capacity selection is dis-
played (150.1).