Configuration Mode

Step-by-Step Instructions
for CONF Mode
Return to normal
operating mode by
pressing the SW-1
switch.
12
7. Press the TEST key to perform this test...
8. Press the TEST key to stop the test . . .
The configuration (CONF) mode menu lets you
configure the scale to your specific application.
The items you can configure are as follows:
FILT (FILTER) – Adjusts the scale's response to
fit environment. Factory default setting is FAST.
BAUD (BAUD) – Allows selection of appropriate
baud rate and parity for computer interface.
Factory default setting is 96-E.
1. Press SW-1. . .
2. Press the ZERO key. . .
3. Press the TEST key. . .
4. Press the TEST key. . .
Model 7815 Parcel Bench Scale User's Manual
Indicates internal A/D raw count. When
weight is applied, the count value should
increase proportionately.
The remaining selections are for viewing
current settings only. You can scroll
through the menu to verify the settings,
but to make changes, you must enter
configuration or calibration.
DIAG is displayed.
CONF is displayed.
FILT is displayed.
The present filter setting is displayed.
The two choices are FAST and SLO.
When the proper selection