Technical Specifications
Physical characteristics
Memory and processor
Mounting
Performance
Environment
Electrical characteristics Frequency
Safety
Emissions
Notes
Services
tr>
Standards and protocols
(applies to all products in series)
BGP
Dimensions
Weight
1 GB SDRAM, 512 MB flash; packet buffer size: 3 MB
Mounts in an EIA-Standard 19-inch telco rack or equipment cabinet (hardware included)
1000 Mb Latency
10 Gbps Latency
Throughput
Routing/Switching
capacity
Routing table size
MAC address table size
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Acoustic
Maximum heat
dissipation
Maximum power rating
Notes
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part 2; IEC
60950-1; EN 60950-1; CAN/CSA-C22.2 No. 60950-1; FDA 21 CFR Subchapter J; ROHS Compliance; AS/NZS
60950-1; GB 4943
EN 55022 Class A; CISPR 22 Class A; EN 55024; ICES-003 Class A; CISPR 24; AS/NZS CISPR 22 Class A; EN
61000-3-2; EN 61000-3-3; GB9254; VCCI-3 CLASS A; VCCI-4 CLASS A; ETSI EN 300 386; FCC Part 15 (CFR
47) CLASS A; YD/T993
8-port Gig-T and SFP modules (JG313A and JG314A) are supported only in slot 1 of this switch.
Refer to the HP website at: www.hp.com/networking/services for details on the service-level
descriptions and product numbers. For details about services and response times in your area, please
contact your local HP sales office.
DA - 14201 Worldwide — Version 20 — April 15, 2014
17.32(w) x 14.17(d) x 1.72(h) in (43.99 x 35.99 x 4.37 cm) (1U height)
16.53 lb (7.5 kg)
< 5 µs
< 3 µs
up to 130.9 million pps
176 Gbps
12000 entries (IPv4), 6000 entries (IPv6)
32000 entries
32°F to 122°F (0°C to 50°C)
5% to 95%, noncondensing
-40°F to 158°F (-40°C to 70°C)
5% to 95%, noncondensing
Low-speed fan: 48.3 dB, High-speed fan: 54.0 dB
50/60 Hz
460 BTU/hr (485.3 kJ/hr)
135 W
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.
IPv6
RFC 1881 IPv6 Address Allocation Management