Test Mode; Caution When Using The Test Mode; Test Mode Settings; Releasing The Test Mode - Sony ZS-M7 Service Manual

Personal minidisc system
Table of Contents

Advertisement

4-1. CAUTIONS WHEN USING THE TEST MODE
1 Check to make sure the inserted disk is completed stopped be-
fore removing since loading related operations will operate re-
gardless of the Test mode operation.
The rotation of the inserted disk will not stop even when press-
ing the MD EJECT button during continuous playback and con-
tinuous recording.
In this case, the disk will be ejected while still in motion.
Always press the CANCEL/NO button and check to see that
the disk has stopped turning before pressing the MD EJECT
button.
2 In the Test mode, detection of the write-protect tab is executed.
For this reason, pressing the REC button in modes where the
recording laser is emitted (see 3-1-1) will delete the recorded
contents regardless of the tab position. When using a disk in the
Test mode which its contents must not be deleted, avoid enter-
ing the Continuous Recording mode and Transverse Adjustment
mode.
4-1-1. Modes which the record laser is emitted and
button operations
• Continuous Recording mode (CREC MODE)
• Traverse Adjustment mode (EFBAL ADJUST)
• Laser Power Adjustment mode (LDPWR ADJUST)
• Laser Power Check mode (LDPWR CHECK)
• Traverse (MO) check (EF MO CHECK)
• Traverse (MO) adjustment (EF MO ADJUST)
• When pressing the REC button

4-2. TEST MODE SETTINGS

MD Test mode :
Press and hold the EDIT button and BASS/TREBLE button,
then press MD ^ n MD p n MD ^ n MD p.
CD Test mode :
Press and hold the EDIT button and BASS/TREBLE button,
then press CD ^ n CD p n CD ^ n CD p.
Display Test mode :
Press and hold the EDIT button and BASS/TREBLE button,
then press BAND n LINE n BAND n LINE (FUNCTION
is LINE).
Note 1 : Each test mode can be entered regardless of whether the power is
on or off. However, it is not possible to enter the test mode of the
particular function being operated. For example, it its not pos-
sible to enter the CD Test mode when the CD is in function.
Note 2 : When entering the MD Test mode, EEPROM data for the radio
broadcasting station names are automatically cleared. To exit the
MD Test mode with sufficient memory, always use the RESET
button. Moreover, never make radio presets once in the MD Test
mode until the mode is exited.

4-3. RELEASING THE TEST MODE

Press the RESET button located on the rear.

4-4. BASIC OPERATIONS OF THE TEST MODE

All operations are made using the AMS dial, ENTER/YES button
and CANCEL/NO button.
The functions of each button are as follows:
Function Name
AMS dial
Used to change parameters and modes
ENTER/YES button
Used to advance and confirm
CANCEL/NO button
Used to return and cancel
SECTION 4

TEST MODE

Functions
– 30 –

4-5. SELECTING THE TEST MODE

There are 9 types of test modes (see table below). Turning the AMS
dial clockwise switches modes shown in the table in the order from
top to bottom. Turning the AMS dial counterclockwise switches
modes shown in the table in the reverse order.
Display
TEMP ADJUST
Temperature compensation offset adjustment
LDPWR ADJUST
Laser power adjustment
LDPWR CHECK
Laser power check
EF BAL ADJUST
Traverse adjustment
FBIAS ADJUST
Focus bias adjustment
FBIAS CHECK
Focus bias check
CPLAY MODE
Continuous playback mode
CREC MODE
Continuous recording mode
EEP MODE
Non-volatile storage memory control
• For details on each adjustment mode, see respective items of SEC-
TION 5. ADJUSTMENT
• If you have accidently entered another mode, press the CANCEL/
No button to exit.
• The EEP MODE is not used during servicing. Thus, details on
this mode are not given. If this mode is accidently entered, exit
immediately by pressing the CANCEL/NO button as the unit may
not operate correctly if the non-volatile storage memory being
overwritten.
4-5-1. Operating in the Continuous Playback mode
1. Entering the Continuous Playback mode
1 Insert a disk into the unit (either recordable or playback disk)
2 Turn the AMS dial until "CPLAY MODE" is displayed.
3 Press the ENTER/YES button. The display will change to
"CPLAY IN".
4 When accessing is completed, the display will change to "C1=
AD =
".
Note : The numbers of "
" displayed indicate the error rate and
"ADER".
2. Changing the playback location
1 Pressing the YES button during continuous playback will
change the display in the following manner, enabling change
in the playback location.
"CPLAY MID" n "CPLAY OUT" n "CPLAY IN"
2 When accessing is completed, the display will change to "C1=
AD =
".
Note : The numbers of "
" displayed indicate the error rate and
"ADER".
3. Exiting the Continuous Playback mode
1 Press the CANCEL/NO button. The display will change to
"CPLAY MODE".
2 To remove the disk, press the MD EJECT button.
Note :
The playback initiate addresses of IN, MID and OUT are indi-
cated below. To display the playback position, press the DIS-
PLAY button and "CPLAY(
IN
40h cluster
MID
300h cluster
OUT
700h cluster
Description
)".