Receiver Adjustment - Icom IC-R2 Service Manual

Communications receiver
Hide thumbs Also See for IC-R2:
Table of Contents

Advertisement

5-3 RECEIVER ADJUSTMENT

ADJUSTMENT
ADJUSTMENT CONDITION
VHF
1
• Displayed frequency :
SENSITIVITY
• Connect an SSG to the antenna
connector and set as :
Level
Modulation : 1 kHz
Deviation : ±3.5 kHz
• Receiving
UHF
1
• Displayed frequency :
SENSITIVITY
• Connect an SSG to the antenna
connector and set as:
Level
Modulation : 1 kHz
Deviation : ±3.5 kHz
• Receiving
S-METER
1
• Displayed frequency :
• Connect the SSG to the antenna
connector and set as :
Level
Modulation : 1 kHz
Deviation : ± 3.5 kHz
• Receiving
2
• Displayed frequency :
• Set the SSG as :
Level
• Receiving
• Displayed frequency :
3
• Set the SSG as :
Level
• Receiving
4
• Displayed frequency :
• Set the SSG as :
Level
• Receiving
5
• Displayed frequency :
• Set the SSG as :
Level
• Receiving
6
• Displayed frequency :
• Set the SSG as :
Level
• Receiving
*This output level of the standard signal generator (SSG) is indicated as SSG's open circuit.
(tk ch)
145.600 MHz
: 1 µV
(–107 dBm)
*
(tk ch)
435.600 MHz
: 1 µV
(–107 dBm)
*
(RS ch)
14.100 MHz
: 0.5 µV
(–113 dBm)
*
(RS ch)
145.100 MHz
: 0.5 µV
(–113 dBm)
*
(RS ch)
200.100 MHz
: 0.5 µV
(–113 dBm)
*
(RS ch)
435.100 MHz
: 0.5 µV
(–113 dBm)
*
(RS ch)
650.100 MHz
: 0.5 µV
(–113 dBm)
*
(RS ch)
1100.100 MHz
: 1 µV
(–107 dBµ)
*
MEASUREMENT
UNIT
LOCATION
RF
Connect
the
DC
voltmeter
to
the
check point SEN.
RF
Connect
the
DC
voltmeter
to
the
check point SEN.
5 - 5
ADJUSTMENT
VALUE
UNIT
Maximum DC voltage
LOGIC
Maximum DC voltage
LOGIC
Push and hold the [MOD] key.
• Verify that S-Meter shows S4 (3dots).
POINT
ADJUST
[DIAL]
[DIAL]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents