Jun. 2011
5-3 RECEIVER ADJUSTMENT
ADJUSTMENT
ADJUSTMENT CONDITIONS
PIN ATT
1 • Frequency
• Mode
• Receiving
HF
1 • Frequency
SENSITIVITY
• Mode
• [10dB]
• [AGC]
• Connect an SSG to the antenna connector
for 0.1–30 MHz (50 Ω ANT) and set as;
Frequency
Level*
Modulation
• Receiving
2 • Set the SSG as;
Level
• Receiving
1ST MIXER
1 • Frequency
BIAS VOLTAGE
• Receiving
HPF SHIFT
1 • Frequency
VOLTAGE
• Mode
• Receiving
2 • Frequency
• Receiving
NOTE: Before adjusting WFM SENSITIVITY, 5-4 RF-C BPF TUNED VOLTAGE must be adjusted.
SENSITIVITY
1 • Frequency
(WFM)
• Mode
• Connect an SSG to the antenna connector
for 30–2000 MHz and set as;
Frequency
Level*
Modulation
Deviation
• Receiving
(FM)
2 • Frequency
• Mode
• Connect an SSG to the antenna connector
for 30–2000 MHz and set as;
Frequency
Level*
Modulation
Deviation
• Receiving
3 • Set the SSG as;
Level*
Modulation
4 • Set the SSG as;
Level
1ST IF
1 • Frequency
NOTCH
• Mode
• Connect an SSG to the antenna connector
for 30–2000 MHz and set as;
Frequency
Level*
Modulation
Deviation
• Receiving
*; This output level of the SSG is indicated as SSG's terminated circuit.
(Replacement page)
UNIT
: 14.10000 MHz
RF-C
: USB
: 14.09850 MHz
Rear
: USB
panel
: ON
: Fast
: 14.10000 MHz
: 0.56 µV (–112 dBm)
: OFF
: OFF
: 173.00000 MHz
RF-D
: 1300.00000 MHz
CONV-B Connect a digital
: FM
: 1100.00000 MHz
: 173.02000 MHz
MAIN-A
: WFM
: 173.02000 MHz
: 3.2 µV (–97 dBm)
: 1 kHz
: ±75 kHz
: 173.02000 MHz
Front
: FM
panel
: 173.02000 MHz
: 3.2 µV (–97 dBm)
: 1 kHz
: ±5 kHz
MAIN-A
: 32 µV (–77 dBm)
: None
Front
: OFF
panel
: 788.60000 MHz
Front
: FM
panel
: 810.00000 MHz
: 32 mV (–17 dBm)
: 1 kHz
: ±75 kHz
5 - 3
MEASUREMENT
LOCATION
Connect a digital
multimeter to CP1.
C o n n e c t a n A C
Maximum output
voltmeter to the [EXT
SP] with an 8 Ω load.
Minimum output
Connect a digital
2.9–3.1 V
multimeter to CP1.
multimeter to CP2.
2.0–4.0 V
Connect a digital
Minimum
multimeter to CP4.
(Note the voltage
as the reference)
S-meter
Maximum
Connect a digital
The same voltage
multimeter to CP5.
on "SENSITIVITY
(WFM)."
The center
indicator
disappears.
Center indicator
S-meter
Maximum
ADJUSTMENT
POINT
VALUE
UNIT
ADJUST
1.7 V
RF-C
R63
Adjust in
level
sequence
L65, L66,
L63, L62
(repeatedly)
R77
level
RF-D
R109
14.5 V
CONV-B
R55
Verify
MAIN-A
Adjust in
level
sequence
L7, L8, L9,
L10
(repeatedly)
MAIN-A
Adjust in
level
sequence
L14, L17,
L22, L25,
L26
(repeatedly)
MAIN-A
R60
AFC
RECV
MIX-A
L15
level
Need help?
Do you have a question about the IC R8500 and is the answer not in the manual?
Questions and answers