Troubleshooting Cip - Hitachi US7070447-001 Troubleshooting Manual

Hispeed fast ethernet switch
Table of Contents

Advertisement

HiSpeed Switch Troubleshooting Guide

Troubleshooting CIP

Problem:
Solution:
11-8
I've created a CIP service but still cannot connect to the ATM
network.
Use the following solutions:

Verify that the CIP service has been created, admin status is enabled,
and protocol state is 'active'.
/ATM/SHOW/cip
/ATM/CONFIG/ENABLE/cip <cip id>

If using SVC connections, ensure that the ATM port is configured for
SVC mode and ILMI is enabled. By default, the ATM port is set to
'PVC' mode and ILMI is disabled.
/ATM/CONFIG/MODIFY> port

If using SVC connections, ensure that you are using the same UNI
signaling version as that of the connected ATM switch.
/ATM/CONFIG/MODIFY >port

If using SVC connections, ensure that you are using the same UNI
signaling version as that of the connected ATM switch.
/ATM/CONFIG/MODIFY >port

If using SVC, verify that the ATM address of the ARP Server is
correct. Also, verify the ARP Server is up and active on the switch
you are connecting to.
 Verify the following using
OAM is up.
SSCOP, and ILMI is up. (for SVC only)
A CIP SVC or PVC connection is created per CIP instance.
ATM port connection and signaling. Operational status, Line
state, Signaling status, and ILMI should be 'up'. (for SVC only)
/ATM/CONFIG/MODIFY> port
 Verify the connection up time is increasing and status is 'active'
for a specific VCC using
<cip id>
/ATM/SHOW/connection:
VAC <VCC number>
Draft Level—Hitachi Confidential
US7070447-001, Rev 01