Remote Panel - Westerbeke 8.0 KW-60Hz SBEG Operator's Manual

Marine gasoline generators
Hide thumbs Also See for 8.0 KW-60Hz SBEG:
Table of Contents

Advertisement

. STARTING/STOPPING PRO
GENERATOR CONTROL PANEL
AC CIRCUIT
IrITii~~~
BREAKER
----+.Ii
HOURMETER
BA FUSE---_W
EMERGENCY"
","_L ,
"00
5
' START/STOP
o
SWITCH
- - " " " ' __ -""
p
m
Starting
Simply press the START switch and the generator will start.
A green light will glow indicating the generator is running.
Stopping
To stop-depress the STOP side of the start switch, the green
light will go out and the generator is stopped.
Failure to Start
The start cycle will automatically tenninate if the unit fails to
start after 12-14 seconds of cranking. Wait 20 seconds, then
repeat the start.
If the unit again fails to start, investigate the cause.
Sometimes after servicing the fuel system or changing the
fuel filter, air can accumulate in the fuel line or the throttle
body and prevent starting.
The Schrader valves on the throttle body and the fuel cell are
used to remove trapped air. This air is mixed with fuel and
under high pressure. Follow the
BLEEDING THE FUEL
SYSTEM
instructions in this manual.
START----'STOP
o
REMOTE CONTROL PANEL
ECU CONINECTIONS
~-~.-£'---EN["NE
HARNESS
CONNECTION
FIREBOY, CO DETECTOR
AND/OR AUXILIARY STOP
CONNECTION
REMOTE START/STOP PANEL
The components on the panel are:
1. A three position start/stop rocker switch.
2. A green LED run indicator light on the rocker switch.
3. A four position LED fault shut down display board.
The start/stop rocker switch functions the sarne as the
start/stop rocker switch on the generator's control panel as
previously explained.
The start/stop rocker switch indicator light on the rocker
switch will illuminate when the start circuit is energized.
It
will go dim as the engine cranks and will brighten as the
engine sttuts to indicate the generator is running.
The LED fault shut down display board has four separate LED
lights to display to the operator the cause of the generators
automatic shut down. The four LED displays are: low oil
pressure, high engine operating temperature, high exhaust
temperature and engine over-speedlunder-speed (flashes).
Should the generator shut down from one of these faults, the
fault LED will remain illuminated. To reset the LED, the stop
switch must be momentarily depressed.
This remote panel is a plug-in accessory and is available with a
15'
to 100' wiring harness .
~
WESTERBEKE
Engines
&
Generators
7