Battery Care - Westerbeke 8.0 KW-60Hz SBEG Operator's Manual

Marine gasoline generators
Hide thumbs Also See for 8.0 KW-60Hz SBEG:
Table of Contents

Advertisement

-'
DC ELECTRICAL SYSTEM
7.
Now check the voltage between the alternator output ter·
minal (B+) and ground,
If
the circuit is good, the voltage at
the alternator will be the same as the battery, or if an isola·
tor is in the circuit the alternator voltage will be zero,
If
neither of the above is true, a problem exists in the circuit
between the alternator and the battery, Check all the
connections -
look for an opening
in
the charging circuit.
STARTING BATTERY
ALTERNATOR
TESTING THE STARTING
BATTERY IALTERNATOR
(ENGINE RUNNING)
8.
Start the engine again, Check the voltage between the
alternator o\ltput and ground,
The voltage reading for a properly operating alternator
should be between 13.5 and 14,5 volts.
If
your alternator
is over· or under-charging, have it repaired at a reliable
service facility.
NOTE:
Before rerrwving the altemator for repair, use a
voltmeter to ensure that
12
volts DC excitation
is
present
at the EXC terminal
if
the previous test showed only bat·
tery voltage at the B output terminal,
If
12
volts is Mt present at the EXC terminal, trace th,e
wiring and look for breaks and poor connections,
12 VOLT DC CONTROL CIRCUIT
The engine has a 12 volt DC electrical control circuit that is
shown on the wiring diagrams that follow. Refer to these
diagrams when troubleshooting or when servicing the DC
electrical system,
A
CAUTION:
To avoid damage to the battery charging
circuit, never shut off the engine battery switch while
the engine is running. Shut off the engine battery switch,
however, to avoid electrical shorts when working on the
engine's electrical circuit.
BATTERY
The recommended "dedicated" battery used for the engine's
starting 12 volt DC control circuit should be 800·1000 Cold
Cranking Amps (CCA) rated,
Checking the Service Battery
Check the voltage of the service battery, This battery should
have a voltage between 13 and 14 volts when the engine is
running,
If
not, there is a problem in the service battery
charging circuit. Troubleshoot the service battery charging
circuit by checking the wiring and connections, the solenoid,
isolator, battery switch, and the battery itself,
MULTIMETER
GROUNO
, ALTERNATOR
: BATTERY SWITCHt?i",-
, SERVICE BATTERY
TESTING THE SERVICE
BATTERY (ENGINE RUNNING)
A
CAUTION:
To avoid damaging the alternator
diodes, do not use a hIgh voltage tester (i.e. a megger)
when perfonnlng tests on the alternator charging circuit.
Battery Care
Review the manufacturer's recommendations and then
establish a systematic maintenance schedule for your engine's
starting batteries and house batteries,
o
Monitor your voltmeter for proper charging during engine
operation.
o
Check the electrolyte level and specific gravity witl) a
hydrometer,
o
Use only distilled water to bring electrolytes to a proper
level.
o
Make celtain that battery cable connections are clean and
tight to the battery posts (and to your engine),
o
Keep your batteries clean and free of corrosion,
A
WARNING:
Sulfuric acid in lead batteries can
cause severe burns on skin and damage clothing. Wear
protective gear.
Engines
&
Generators
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

10.0 kw-5

Table of Contents