OPTIONAL REMOTE CONTROL PANELS
OPERATING INSTRUCTIONS
DESCRIPTION
There are several options available when selecting remote
operation of your generator.
1. Mo'unt a second (repeating) Instrument Control Panel in a
remote location.
2. Simply remove the Instrument Control Panel from the
control box and mount it as a remote panel.
NOTE: The Instrument Control Panel can be replaced by
installing a basic start/stop panel in the control box.
3. Mount a remote start/stop control panel ina remote
location.
The remote )?anels connect
to
the 15 pin plug on the back of
the control box using the extension harnesses listed below.
EXTENSION HARNESS
PN#056236 EG DIESEL (8 PIN) 15FT
PN#056235 EG DIESEL (8 PIN) 30FT
REMOTE START/STOP PANEL· DESCRIPTION
The Remote Start/Stop Panel has the same three rocker
switches as the Instrument Control Panel. Their function is
the same. This panel has a RELEASE STARTER LED. This
LED will illuminate when the PREHEAT is depressed. When
this panel is remote mounted, this LED will indicate when
the generator has started. When depressing the START
rocker switch, this LED will dim. When the generator starts,
the LED will brighten. This indicates to release the START
rocker switch. The PREHEAT rocker switch is held
depressed for about 4-5 seconds to allow the oil pressure to
reach 10 psi, then release it.
For the REMOTE START/STOP PANEL wiring diagram
and wiring harness, refer to the Table of Contents.
INSTRUMENT
CONTROL PANEL(AS
A REMOTE PANEL)
PN56246
REMOTE START/STOP PANEL
PN56320