8. Appendix

8.1

Faults and Warnings Overview

Fault or warning conditions are indicated by the LED shown in Figure 6-3 on page 16. As the LED indicates
several types of faults or warnings, a brief textual description of the fault or warning is provided on the LCD
display. Section on page 19 details the fault and warning indications that appear on the front panel. Table 8-1
lists the events that may have triggered each fault or warning condition.
LCD Text
Event Log Text
ANALOG IN
Frame Fault:
FAULT
Analog Input
CLOCK
AES Clock
SLIPPING
Slipping
CTRL OFFLINE
-
Frame Fault: Fan
FAN FAULT
error
INPUT MUTE
Input X Mute
NO INPUT
No Input Source
Temp Fault: DSP
OVERTEMP
area
PROTECTIVE
Protective mute
MUTE
via GPIO
TEMP
Temp Warning:
WARNING
DSP area
-
Frame Offline
Module Input
-
Mute
Module Output
-
Mute
Sound Source
Changed
Table 8-1: Warning, Fault and Mute Indications (alphabetical by LCD Text / Event Log Text)
Type
Description / Troubleshooting
There is a problem with the analog input. Verify signal and connec-
Fault
tions.
The selected digital clock and digital input combination is not
Warning
aligned. Verify digital input configuration to ensure all clock settings
match.
The LM 26 is no longer able to communicate with the Lake Control-
Warning
ler. Check network connectivity.
There is a problem with the fan on the LM 26. To avoid overheat-
Fault
ing, identify and fix the problem immediately.
An input is muted; all Modules and outputs sourced from this input
Mute
will be affected.
No input signal of any type can be identified. Connect an input
Fault
source, or verify input signals and connections.
The temperature has reached a critical 70
Fault
off or take steps to cool the unit immediately; continued operation
cannot be guaranteed.
A processor mute state has been triggered via GPIO. Change this
Event
setting using the external control device.
The temperature has reached 55
Warning
ture and take additional steps to reduce temperature if it continues
to increase.
The Lake Controller is no longer able to communicate with the LM
Warning
26. Check network connectivity.
A Module Input has been muted. The mute is identified via the
Mute
associated Module Input mute button on the front panel.
A Module Output has been muted. The mute is identified via the
Mute
associated Module Output mute button on the front panel.
The input source has been changed either manually or by automatic
Warning
input priority detection.
C (158
F). Turn the unit
o
o
C (131
F ). Monitor the tempera-
o
o
LM 26 Operation Manual rev 1.1.8
Appendix
45