Lab.gruppen Lake LM 26 Operation Manual page 39

Digital audio loudspeaker processor
Table of Contents

Advertisement

Front Panel Interface
6.10.4.2 Frame Reset
MENU > FRAME > RESET
Use this option to display a further menu with options to reset all parameters back to their original factory
default values. See section 8.3 for a full list of these values. Two types of reset are provided, Factory Reset
and Soft Reset.
Factory Reset
A Factory Reset will reset all settings and parameters to the original factory-defined default values. This
includes the deletion of any Frame Presets stored within the device. It also resets the IP Address and all
network related settings; a hard power cycle is required to complete this reset.
Soft Reset
A Soft Reset will reset all settings and parameters to the original factory-defined default values, but retains
Frame Preset information and IP / Network configuration. A power cycle is not required to complete this
type of reset.
6.10.4.3 Latency Match
To turn Latency Match on or off, select the parameter using the adjacent button then change the status
using the rotary encoder.
When Latency Match is ON the LM 26 adds delay to match the overall processing delay of legacy Lake
Contour Pro 26 and Mesa Quad EQ products. Please refer to the Lake Controller Operation Manual for
further information.
6.10.4.4 GPIO
MENU > FRAME > GPIO
Figure 6-18: GPIO Menu
Four general purpose input/output configuration settings are available; two configuration options for inputs,
and two for outputs.