Fujitsu D2109 Technical Manual

System board and sas controller for tx200 s3

Advertisement

PRIMERGY
Susanne Däschlein
Fujitsu Siemens Computers GmbH München
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 61001-155
Fax: (++49) 700 / 372 00000
D2109 (TX200 S3)
Sprachen: En

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2109

  • Page 1 PRIMERGY Susanne Däschlein Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-155 Fax: (++49) 700 / 372 00000 D2109 (TX200 S3) Sprachen: En...
  • Page 2 Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2006 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Replacing the lithium battery ....Abbreviations ....... Technical Manual D2109 (TX200 S3)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2109, which can be ® equipped with one or two Intel processors. Further information about drivers is provided in the readme files on the hard disk, on the supplied "ServerStart" or "Update" CDs.
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2109 (TX200 S3)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2109 (TX200 S3)
  • Page 9 Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2109 (TX200 S3)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2109 (TX200 S3)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2109 (TX200 S3)
  • Page 12 You will find further information on this at www.fujitsu- siemens.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
  • Page 13: Features

    – Integrated VGA controller with PCI 32 Bit/33 MHz – Super I/O controller (SMSC DME1737) – Flash EPROM for: – SCSI-BIOS – BIOS – LAN – server management (SM) – server management with iRMC (FSC System) Technical Manual D2109 (TX200 S3)
  • Page 14 – 2 x PCI-X (64 bit / 100/133 MHz IOOP – 1 x PCI-Express (2 Gbyte/s bandwidth) – 1 x PCI-Express (4 Gbyte/s bandwidth) – 1 x PCI 2.3 (32 bit / 33 MHz) – 1 x PCI-X only for SAS controller D2107 Technical Manual D2109 (TX200 S3)
  • Page 15 – 120 MB floppy disk drive – CD-ROM/DVD – Festplatte – LAN – console redirection support – OEM logo – CPU, memory disable – hotspare memory support Environmental protection battery in holder Form factor 302 x 415 mm Technical Manual D2109 (TX200 S3)
  • Page 16: Main Memory

    FBD533/PC2-4200F or FDB667/PC2-5300 fully buffered DIMM modules and must be populated in pairs. It is only allowed you use memory modules released by Fujitsu Siemens Computers. – Each pair must consist of identical memory modules (2 way interleaved mode).
  • Page 17: Pci Bus

    The following table shows an overview of the PCI slots: PCI slot 64bit/ Frequency Description 32bit in MHz 64 bit 100/133 64-bit PCI-X slots, 133 MHz only if one of the three slots (1,2,or 10) is populated 64 bit 100/133 Technical Manual D2109 (TX200 S3)
  • Page 18 PCI slot 1 (blue sockel) is prepared for Zero Channel RAID (ZCR). ZCR means that the SCSI controller is seen as SCSI RAID controller through the inserted SAS controller D2107. The PCI bus then runs with 100 MHz. Technical Manual D2109 (TX200 S3)
  • Page 19: Isa Bus Resources

    "IRQ" = interrupt assigned as shipped "Address" = this address can be used for your particular device "Address" = this DMA can be used for your particular device Default settings are shown in bold print Technical Manual D2109 (TX200 S3)
  • Page 20: Pci Resources

    3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15 The selected ISA interrupt is assigned to the PCI interrupt. You may not select an ISA interrupt that is used by a component on the system board (e.g. controller) or an ISA board. Technical Manual D2109 (TX200 S3)
  • Page 21: Screen Resolution

    Screen resolution Supported colours 640x480 8 bit, 16 bit, 24 bit 800x600 16 bit, 24 bit 1024x768 16 bit 1152x864 8 bit 1280x1024 8 bit Technical Manual D2109 (TX200 S3)
  • Page 22: Temperature / System Monitoring

    When voltage exceeds warning level high or falls below warning level low an alert will be generated. Cover monitoring Unauthorised opening of the cover is detected, even when the system is switched off. However, this will only be indicated when the system is switched on again. Technical Manual D2109 (TX200 S3)
  • Page 23: Leds

    CPU 1 iRMC CPU 2 Figure 4: LEDs L1 and L2 are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server is open. Technical Manual D2109 (TX200 S3)
  • Page 24 L6 - board green flashing iRMC - server management controller is iRMC not alive L7 - system green fan running fan 1 fan failure L8 - system green fan running fan 2 fan failure Technical Manual D2109 (TX200 S3)
  • Page 25: Interfaces And Connectors

    CPU 1 iRMC CPU 2 Battery Beeper Figure 5: Schematic view of the system board D2109 1 = Printer (optional) 14 = Redundant system fan 2 = DIP switch (see page 28) 15 = System fan 2 3 = Power supply PWR3...
  • Page 26: External Ports

    Interfaces and connectors Features 3.7.1 External ports Figure 6: External ports of the system board D2109 1 = PS/2 mouse connector 6 = VGA port 2 = serial interface COM2 7 = serial interface COM1 3 = USB ports 3 and 4...
  • Page 27 LAN transfer Figure 8: LAN connector service LAN controller 1 LAN transfer rate green transfer rate 10 Mbit/s green transfer rate 100 Mbit/s 2 LAN link/aktivity green LAN connection no LAN connection flashing LAN transfer Technical Manual D2109 (TX200 S3)
  • Page 28: Settings With Switches

    Switch 2 is used to define whether the password is queried at system startup, if the password protection is enabled in BIOS Setup (in Security menu, the Password field must be set to Enabled). The password query is skipped. Passwords are deleted. The password query is effective (default setting). Technical Manual D2109 (TX200 S3)
  • Page 29 To write and delete floppy disks, the write-protection in BIOS Setup must be disabled (in menu Security, the field Diskette Write must be set to Enabled). The floppy disk drive is write-protected. Floppy disks can be read, written and deleted (default setting). Technical Manual D2109 (TX200 S3)
  • Page 31: Sas Controller D2107

    SAS controller D2107 If the system board should support fully SAS functionality, the SAS controller D2109 has to be installed in PCI slot 10. Figure 10: Schematic view of the SAS controller D2107 = SAS connector MLC2 = SAS connector MLC1...
  • Page 33: Scsi/Ime Configuration Program

    This function is not available in all menus Calling the SAS/IME configuration program Start the PC, if the following message appears, press the key combination [CTRL] and [C]: Following hint appears next: Technical Manual D2109 (TX200 S3)
  • Page 34 From there select the depending entry and press the [ENTER] key to change into the submenus. Detailed instruction on the configuration and on the submenus are contained in the manual „Integrated RAID for SAS, User's Guide“. Technical Manual D2109 (TX200 S3)
  • Page 35    Boot Support Enabled BIOS & OS (it is recommended: don’t change this setting) Enabled BIOS only Menu RAID Properties see page Menu SAS Topology see page Menu Advanced Adapter Properties see page Technical Manual D2109 (TX200 S3)
  • Page 36                                    Technical Manual D2109 (TX200 S3)
  • Page 37  Only two RAIDs can be configured on the SAS-Controller 1068. The administration of the RAID system can be set later by a tool in your operating system (see therefore the documentation „Global Array Manager“). Technical Manual D2109 (TX200 S3)
  • Page 38                                    Technical Manual D2109 (TX200 S3)
  • Page 39 CHS Mapping SCSI Plug and Play Mapping (it is recommended: don’t change this setting) Alternate CHS Mapping Menu Advanced Device Properties see page 40. Menu Spinup Properties see page 41. Menu PHY Properties see page 42. Technical Manual D2109 (TX200 S3)
  • Page 40                                    Technical Manual D2109 (TX200 S3)
  • Page 41 „Start Unit“ command from BIOS of the SAS controller. This function is used to distribute the high starting currents of the SAS devices over a specific period and to release the power supply of your server. Technical Manual D2109 (TX200 S3)
  • Page 42                                    Technical Manual D2109 (TX200 S3)
  • Page 43: Replacing The Lithium Battery

    Press the locking spring into direction of of the arrow (1), so that the lithium battery jumps out of its socket. Remove the battery (2). Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2109 (TX200 S3)
  • Page 45: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit Double Data Rate DIMM Dual In-line Memory Module Technical Manual D2109 (TX200 S3)
  • Page 46 EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD Hotplug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus Technical Manual D2109 (TX200 S3)
  • Page 47 Light Emitting Diode Multi Processor Specification Non Maskable Interrupt Original Equipment Manufacturer OHCI Open Host Controller Interfache Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) Technical Manual D2109 (TX200 S3)
  • Page 48 Real Time Clock Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interfache SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide System Management Bus Server Management Mode Technical Manual D2109 (TX200 S3)
  • Page 49 Abbreviations Symmetrically Multi Processing UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2109 (TX200 S3)
  • Page 51 Comments Suggestions Corrections Fax: (++49) 700 / 372 00000 Comments on System Board D2109 for TX200 S3 D2109 (TX200 S3)
  • Page 53 Comments Suggestions Corrections Fax: (++49) 700 / 372 00000 Comments on System Board D2109 for TX200 S3 D2109 (TX200 S3)
  • Page 55 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

This manual is also suitable for:

D2107

Table of Contents