Fujitsu D2119 Technical Manual

Fujitsu D2119 Technical Manual

For rx300 s3

Advertisement

Quick Links

PRIMERGY
System Board D2119
for RX300 S3
Technical Manual
Martin Jung
Fujitsu Siemens Computers GmbH München
81730 München
e-mail: email: manuals@fujitsu-siemens.com
Tel.: (089) 61001-154
Fax: (++49) 700 / 372 00000
D2119 (RX300 S3)
Sprachen: En
Edition May 2006

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu D2119

  • Page 1 PRIMERGY System Board D2119 for RX300 S3 Technical Manual Martin Jung Fujitsu Siemens Computers GmbH München 81730 München e-mail: email: manuals@fujitsu-siemens.com Tel.: (089) 61001-154 Fax: (++49) 700 / 372 00000 D2119 (RX300 S3) Sprachen: En Edition May 2006...
  • Page 2 Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2006 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Replacing the lithium battery ....Abbreviations ....... Technical Manual D2119 (RX300 S3)
  • Page 5: Introduction

    Introduction This technical manual describes the system board D2119, which can be ® equipped with one or two Intel processors. Further information about drivers is provided in the readme files on the hard disk, on the supplied "ServerSupport" or "ServerStart" CDs.
  • Page 7: Important Notes

    Information on which system expansions are suitable can be obtained from the customer service centre or your sales outlet. The warranty expires if the device is damaged during the installation or replacement of system expansions. Technical Manual D2119 (RX300 S3)
  • Page 8 Incorrect replacement of lithium battery may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer. It is essential to observe the instructions in chapter “Replacing the lithium battery”. Technical Manual D2119 (RX300 S3)
  • Page 9 Place all components on a static-safe base. You will find a detailed description for handling ESD components in the relevant European or international standards (EN 61340-5-1, ANSI/ESD S20.20). Technical Manual D2119 (RX300 S3)
  • Page 10: Ce Certificate

    Never use sharp objects (screwdrivers) for leverage. CE Certificate The shipped version of this board complies with the requirements of the EEC directive 89/336/EEC "Electromagnetic compatibility". Compliance was tested in a typical PRIMERGY configuration. Technical Manual D2119 (RX300 S3)
  • Page 11: Environmental Protection

    Cd Cadmium Hg Mercury Pb Lead Notes on labeling plastic housing parts Please avoid attaching your own labels to plastic housing parts wherever possible, since this makes it difficult to recycle them. Technical Manual D2119 (RX300 S3)
  • Page 12 You will find further information on this at www.fujitsu- siemens.com/recycling. For details on returning and reuse of devices and consumables within Europe, refer to the “Returning used devices” manual, or contact your Fujitsu Siemens Computers branch office/subsidiary or our recycling centre in Paderborn: Fujitsu Siemens Computers...
  • Page 13: Features

    – Flash for SAS-BIOS and NVRAM for integrated mirroring – Flash and NVRAM for RAID – Integrated VGA controller with PCI 32 Bit/33 MHz – Super I/O controller (SMSC DME1737) – Flash EPROM for: – SCSI-BIOS – BIOS – LAN Technical Manual D2119 (RX300 S3)
  • Page 14 – second serial port (COM2) (optional) – 1 parallel port (optional) – 2 PS/2 interfaces for keyboard and mouse – 2 USB 2.0 ports with 480 Mbits/s (rear side) – 1 VGA port – 2 RJ45 LAN ports Technical Manual D2119 (RX300 S3)
  • Page 15 – 120 MB floppy disk drive – CD-ROM/DVD – Festplatte – LAN – console redirection support – OEM logo – CPU, memory disable – hotspare memory support Environmental protection battery in holder Form factor 290 x 480 mm Technical Manual D2119 (RX300 S3)
  • Page 16: Main Memory

    – The memory modules have to be based on FBD533/PC2-4200F or FBD667/PC2-5300 fully buffered DIMM modules and must be populated in pairs. – Each pair must consist of identical memory modules (2 way interleaved mode). Technical Manual D2119 (RX300 S3)
  • Page 17 Memory Mirroring Memory Mirroring needs 4 or 4+4 identical memory modules: Memory bank Channel (module) identical memory modules Population identical memory modules identical memory modules Technical Manual D2119 (RX300 S3)
  • Page 18: Pci Bus

    PCI-Express x8 slot; prepared for riser card Hot-plug PCI PCI slots 3 and 4 are hot-plug capable. Optional riser card PCI slots 5 is prepared for an extension by a riser card with 3 x 64-bit slots. Technical Manual D2119 (RX300 S3)
  • Page 19: Isa Bus Resources

    "IRQ" = interrupt assigned as shipped "Address" = this address can be used for your particular device "Address" = this DMA can be used for your particular device Default settings are shown in bold print Technical Manual D2119 (RX300 S3)
  • Page 20: Pci Resources

    3, 4, 5, 6, 7, 9, 10, 11, 12, 14, 15 The selected ISA interrupt is assigned to the PCI interrupt. You may not select an ISA interrupt that is used by a component on the system board (e.g. controller) or an ISA board. Technical Manual D2119 (RX300 S3)
  • Page 21: Screen Resolution

    Screen resolution Supported colours 640x480 8 bit, 16 bit, 24 bit 800x600 16 bit, 24 bit 1024x768 16 bit 1152x864 8 bit 1280x1024 8 bit Technical Manual D2119 (RX300 S3)
  • Page 22: Temperature / System Monitoring

    System Event Log (SEL) All monitored events of the system board are signalised via the Global Error LED and recorded in the System Event Log. They could be retrieved in the BIOS Setup or via ServerView. Technical Manual D2119 (RX300 S3)
  • Page 23: Leds

    CPU 2 Battery L25 L27 Figure 4: LEDs L1 and L2 are visible from outside on the rear of the server. All the other LEDs are only visible, if the cover of the server is open. Technical Manual D2119 (RX300 S3)
  • Page 24 4, module DIMM-2C memory bank 2, module DIMM-1C memory bank 3, module DIMM-2B memory bank 1, module DIMM-1B memory bank 3, module DIMM-2A memory bank 1, module DIMM-1A L16 - CPU orange flashing error in CPU1 Technical Manual D2119 (RX300 S3)
  • Page 25 CPU fan 1 CPU fan 2 CPU fan 4 CPU fan 5 CPU fan 3 system fan 1 CPU fan 6 system fan 2 Technical Manual D2119 (RX300 S3)
  • Page 26: Interfaces And Connectors

    CPU 1 iRMC CPU 2 Battery Figure 5: Schematic view of the system board D2119 1 = Parallel port (optional) 13 = RAID key 2 = Slots for main memory modules 14 = RAID DIMM 3 = Stromversorgung 12V + PC98 15 = KVM power...
  • Page 27: External Ports

    Features Interfaces and connectors 3.7.1 External ports Figure 6: External ports of the system board D2119 1 = PS/2 mouse connector 6 = serial interface COM1 2 = USB ports 1 and 2 7 = PS/2 keyboard connector 3 = LAN2 connector...
  • Page 28 1 LAN transfer rate green + transfer rate 10 Mbit/s (or no yellow connection) green transfer rate 100 Mbit/s yellow transfer rate 1000 Mbit/s 2 LAN link/aktivity green LAN connection no LAN connection flashing LAN transfer Technical Manual D2119 (RX300 S3)
  • Page 29: Settings With Switches

    Switch 2 is used to define whether the password is queried at system startup, if the password protection is enabled in BIOS Setup (in Security menu, the Password field must be set to Enabled). The password query is skipped. Passwords are deleted. The password query is effective (default setting). Technical Manual D2119 (RX300 S3)
  • Page 30 To write and delete floppy disks, the write-protection in BIOS Setup must be disabled (in menu Security, the field Diskette Write must be set to Enabled). The floppy disk drive is write-protected. Floppy disks can be read, written and deleted (default setting). Technical Manual D2119 (RX300 S3)
  • Page 31: Sas And Raid

    This function is not available in all menus Calling the SAS/IME configuration program Ê Start the PC, if the following message appears, press the key combination [CTRL] and [C]: „Press Ctrl-C to start LSI Logic Configuration Utility“ Technical Manual D2119 (RX300 S3)
  • Page 32 Press the [ENTER] key to change into the menu Adapter Properties. Ê From there select the depending entry and press the [ENTER] key to change into the submenus. Detailed instruction on the configuration of IME are contained in the IME User's Guide. Technical Manual D2119 (RX300 S3)
  • Page 33 +/- = Change Item Boot Support Enabled BIOS & OS (it is recommended: don’t change this setting) Enabled BIOS only Menu RAID Properties see page Menu SAS Topology see page Menu Advanced Adapter Properties see page Technical Manual D2119 (RX300 S3)
  • Page 34 ALL DATA on array disks will be DELETED!    ______________________________________________________________________________   Esc = Exit Menu  F1/Shift+1 = Help  Enter = Choose array type to create  Esc = Return to Adapter Properties Technical Manual D2119 (RX300 S3)
  • Page 35 C = Create an array Only two RAIDs can be configured on the SAS-Controller 1068. The administration of the RAID system can be set later by a tool in your operating system (see therefore the documentation „Global Array Manager“). Technical Manual D2119 (RX300 S3)
  • Page 36 SEAGATE ST3146854SS 1501              ______________________________________________________________________________   Esc = Exit  F1 = Help  Alt+D = Device Properties  Alt+M = More Keys Technical Manual D2119 (RX300 S3)
  • Page 37 CHS Mapping SCSI Plug and Play Mapping (it is recommended: don’t change this setting) Alternate CHS Mapping Menu Advanced Device Properties see page 38. Menu Spinup Properties see page 39. Menu PHY Properties see page 40. Technical Manual D2119 (RX300 S3)
  • Page 38  Removable Media support [None]     Restore Defaults    ______________________________________________________________________________   Esc = Exit Menu  F1/Shift+1 = Help  Enter = Select Item  -/+ = Change Item Technical Manual D2119 (RX300 S3)
  • Page 39 „Start Unit“ command from BIOS of the SAS controller. This function is used to distribute the high starting currents of the SAS devices over a specific period and to release the power supply of your server. Technical Manual D2119 (RX300 S3)
  • Page 40         ______________________________________________________________________________   Esc = Exit Menu  F1/Shift+1 = Help  Enter = Reset Phy error logs  Alt+N = Next Phy Alt+P = Previous Phy Technical Manual D2119 (RX300 S3)
  • Page 41: Raid On Motherboard (Romb)

    SAS channels, channel 0 to channel 5. This channels are assigned to the SAS connector. You will find the exact location of the SAS connector in the schematic view of the system board. Technical Manual D2119 (RX300 S3)
  • Page 42 You validate the controller with Start. Start calls the main menu, shown in figure 10. The main menu allows to get all information and settings which are offered by WebBIOS. Figure 9: WebBIOS start page controller selection Technical Manual D2119 (RX300 S3)
  • Page 43 WebBIOS is contained in the „MegaRAID SAS Software User's Guide“. [TAB key] to select a menu item ÊË to modify an item [ENTER] to validate a selection ÀÂ to scroll right or left between a line Technical Manual D2119 (RX300 S3)
  • Page 45: Replacing The Lithium Battery

    Ê Press the locking spring into direction of of the arrow (1), so that the lithium battery jumps out of its socket. Ê Remove the battery (2). Ê Insert a new lithium battery of the same type into the socket (3) and (4). Technical Manual D2119 (RX300 S3)
  • Page 47: Abbreviations

    Automatic Server Recovery and Restart Advanced Technology Attachment Battery Backup Unit BIOS Basic Input Output System Baseboard Management Controller CMOS Complementary Metal Oxide Semiconductor COMmunication port Central Processing Unit Double Data Rate DIMM Dual In-line Memory Module Technical Manual D2119 (RX300 S3)
  • Page 48 EPROM Erasable Programmable Read Only Memory EMRL Embedded RAID Logic EVRD Enterprise VRD Hotplug Controller In Circuit Emulation Integrated (intelligent) Drive Electronics Integrated Mirror Enhanced IOOP Intelligent Organisation Of PCI IPMB Intelligent Platform Management Bus Technical Manual D2119 (RX300 S3)
  • Page 49 Light Emitting Diode Multi Processor Specification Non Maskable Interrupt Original Equipment Manufacturer OHCI Open Host Controller Interfache Operating System Peripheral Components Interconnect Prefailure Detection and Analyzing Programmed Input Output Programmable Logic Device PS(U) Power Supply (Unit) Technical Manual D2119 (RX300 S3)
  • Page 50 Real Time Clock Serial Attached SCSI SATA Serial ATA SCSI Small Computer Systems Interfache SDDC Single Device Data Correction SDRAM Synchronous Dynamic Random Access Memory SHDG Server Hardware Design Guide System Management Bus Server Management Mode Technical Manual D2119 (RX300 S3)
  • Page 51 Abbreviations Symmetrically Multi Processing UHCI Unified Host Controller Interface Universal Serial Bus Video Graphics Adapter Voltage Regulator Down Voltage Regulator Module Wired for Management Wake up On LAN Technical Manual D2119 (RX300 S3)
  • Page 53 Comments Fujitsu Siemens Computers GmbH User Documentation Suggestions 81730 München Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on System Board D2119 for RX300 S3 D2119 (RX300 S3)
  • Page 55 Comments Fujitsu Siemens Computers GmbH User Documentation Suggestions 81730 München Germany Corrections Fax: (++49) 700 / 372 00000 email: manuals@fujitsu-siemens.com http://manuals.fujitsu-siemens.com Submitted by Comments on System Board D2119 for RX300 S3 D2119 (RX300 S3)
  • Page 57 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.