5.3
Connection of the head to Efka DC1550/DA321G drive
20
Efka DC1550/DA321G direct drive is fixed directly on the machine
head. The motor synchronizer is incorporated in the motor body and it
is not located on the hand wheel (this applies, however, only for the
1:1 gear reduction motor – machine).
7 4 1 2
9 3 5
Connect the machine head connecting cable to the connector (1).
Connect the control panel to the connector (2).
Connect connector (3) of the motor synchronizer (6) to
connector (4).
Connect the connector (5) of the motor (6) to the connector (7).
Connect the pedal position sensor (8) to the connector (9).
Connect hand wheel position in connector B18.
6
8