Dell PowerEdge 2450 Installation And Troubleshooting Manual page 59

Dell poweredge 2450 system
Hide thumbs Also See for PowerEdge 2450:
Table of Contents

Advertisement

support.dell.com
4.
Is the battery firmly installed in the battery socket on the system board?
Y es. Go to step 7 .
No. Go to step 6.
5.
Reseat the battery in its socket.
6.
Close the computer doors and reconnect the system to the electrical outlet.
Is the problem resolved?
Y es. The battery was loose. You have fixed the problem.
No. Continue with this procedure.
7 .
Repeat steps 1 and 2.
8.
Replace the battery.
Is the problem resolved?
Y es. The battery's charge was low. You have fixed the problem.
No. See Chapter 11, "Getting Help," for instructions on obtaining technical
assistance.
# $   & ' 
 
Your PowerEdge 2450 system may contain two optional, redundant power supplies.
The two indicators on the back of each power supply (see Figure 7-5) signal the power
supply's current status. If the red (forwardmost) failure indicator lights up, replace the
power supply as described in the following subsection.
Checking Inside the Computer
7-9