Dell PowerEdge 2450 Installation And Troubleshooting Manual page 22

Dell poweredge 2450 system
Hide thumbs Also See for PowerEdge 2450:
Table of Contents

Advertisement

    


 
 

 
 

 
 

 

NOTE: For the full name of an abbreviation or acronym used in this table, see "Abbreviations and Acronyms."
3-6
Dell PowerEdge 2450 Systems Installation and Troubleshooting Guide

Faulty or improperly seated
DIMMs or defective system
board
 
Faulty application
Improperly seated or faulty
DIMMs
POST memory test terminated by
pressing the spacebar
Faulty diskette, diskette/tape
drive subsystem, hard-disk drive,
hard-disk drive subsystem, or no
boot disk in drive A
Incorrect configuration settings in
System Setup program, or no
operating system on hard-disk
drive
Defective system board
   
Remove and reseat the DIMMs.
If the problem persists, replace
the DIMMs. See Chapter 11,
"Getting Help," for instructions
on obtaining technical assistance.
Restart the application.
Remove and reseat the DIMMs.
If the problem persists, replace
the DIMMs. See Chapter 11,
"Getting Help," for instructions
on obtaining technical assistance.
No action is required.
Replace the diskette or hard-disk
drive. If the problem persists,
replace the system board. See
Chapter 11, "Getting Help," for
instructions on obtaining technical
assistance.
Check the hard-disk drive configu-
ration settings in the System
Setup program. See Chapter 4,
"Using the System Setup Pro-
gram," in the User's Guide for
instructions.
Replace the system board. See
Chapter 11, "Getting Help," for
instructions on obtaining technical
assistance.