support.dell.com
   


1-3-2
No memory installed
1-3-3
Chip or data line failure in the
first 64 KB of main memory
1-3-4
Odd/even logic failure in the first
64 KB of main memory
1-4-1
Address line failure in the first
64 KB of main memory
1-4-2
Parity failure in the first 64 KB of
main memory
2-1-1
Bit failure in the first 64 KB of
through
main memory
2-4-4
3-1-1
Slave DMA-register failure
3-1-2
Master DMA-register failure
3-1-3
Master interrupt-mask register
failure
NOTE: For the full name of an abbreviation or acronym used in this table, see "Abbreviations and
Acronyms."
   
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still persists,
replace the system board. See
Chapter 11, "Getting Help," for
instructions on obtaining technical
assistance.
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still persists,
replace the system board. See
Chapter 11, "Getting Help," for
instructions on obtaining technical
assistance.
Remove and reseat the DIMMs. If
the problem persists, replace the
DIMMs. If the problem still persists,
replace the system board. See
Chapter 11, "Getting Help," for
instructions on obtaining technical
assistance.
Replace the system board. See
Chapter 11, "Getting Help," for
instructions on obtaining technical
assistance.