Water Supply Requirements; Electrical Requirements - U.s.a. Only - KitchenAid 30" (76.2 CM) COMMERCIAL STYLE DUAL FUEL CONVECTION RANGE Installation Instructions Manual

30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) commercial style dual fuel convection range
Hide thumbs Also See for 30" (76.2 CM) COMMERCIAL STYLE DUAL FUEL CONVECTION RANGE:
Table of Contents

Advertisement

Available languages

Available languages

Water Supply Requirements

A cold water supply with water pressure between 30 and 120 psi
(207 and 827 kPa) is required to operate the steam feature. In
Massachusetts, plumbing code 248 CMR 3.00 and 10.00 must
be followed and a licensed plumber shall be used. If you have
questions about your water pressure, call a licensed, qualified
plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
range needs to be between 30 and 120 psi (207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 psi (276 kPa).
If the water pressure to the reverse osmosis system is less than
40 psi (276 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If you have questions about your water pressure, call a licensed,
qualified plumber.

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located on the
right vertical surface of the oven door frame. Refer to the
illustrations in the "Product Dimensions" section of the
"Location Requirements" section.
This range may be manufactured with a 4-wire power supply
cord, or it may not include a power supply cord. If your range
does not include a power supply cord, use a 4-wire power
8
supply cord rated at 250 volts, 40 or 50 amps and
investigated for use with ranges.
Range Rating*
120/240 Volts
120/208 Volts
8.8 - 16.5 kW
7.8 - 12.5 kW
16.6 - 22.5 kW
12.6 - 18.5 kW
*The NEC calculated load is less than the total connected load
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with
kit. For 50-amp rated cord kits, use kits that specify use with a
nominal 1 " (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
Wire sizes and connections must conform with the rating of
the range.
The Tech Sheet is located behind the kick plate in a clear
plastic bag.
If connecting to a 4-wire system:
This range is manufactured with the ground connected to the
cabinet. The ground must be revised so the green ground wire of
the 4-wire power supply cord is connected to the cabinet. See
the "Electrical Connection - U.S.A. Only" section.
Grounding through the neutral conductor is prohibited for new
branch-circuit installations (1996 NEC); mobile homes; and
recreational vehicles, or an area where local codes prohibit
grounding through the neutral conductor.
When a 4-wire receptacle of NEMA Type 14-50R is used, a
matching UL listed, 4-wire, 250-volt, 40- or 50-amp, range power
supply cord must be used. This cord contains 4 copper
conductors with ring terminals or open-end spade terminals with
upturned ends, terminating in a NEMA Type 14-50R plug on the
supply end.
The fourth (grounding) conductor must be identified by a green or
green/yellow cover and the neutral conductor by a white cover.
Cord should be Type SRD or SRDT with a UL listed strain relief
and be at least 4 ft (1.22 m) long.
4-wire receptacle (14-50R)
The minimum conductor sized for the copper 4-wire power
cord are:
40-amp circuit
2 No.-8 conductors
1 No.-10 white neutral
1 No.-10 green grounding
Specified Rating of Power
Supply Cord Kit and
Circuit Protection
Amps
Range Size
40 or 50**
30" (76.2 cm),
36" (91.4 cm)
50
48" (121.9 cm)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents