Specifications - Extech Instruments MN16A User Manual

Autoranging mini multimeter
Table of Contents

Advertisement

Specifications

Function
Range
DC Voltage
4V
(V DC)
40V
400V
600V
AC Voltage
400mV*
(V AC)
4V
(50 / 60Hz)
40V
400V
600V
*400mV range is not autoranging
DC Current
400μA
(A DC)
4000μA
40mA
400mA
10A
AC Current
400μA
(A AC)
4000μA
40mA
400mA
10A
Resistance
400Ω
4kΩ
40kΩ
400kΩ
4MΩ
40MΩ
40nF
Capacitance
400nF
4μF
40μF
100μF
Duty Cycle
0.1 to 99.9%
pulse width range: 100µs - 100ms (Frequency: 5Hz to 150kHz)
Temp (type-K)
-4 to 1400°F
-20 to 750°C
Resolution
Accuracy
0.001V
±(1.2% reading + 2 digits)
0.01V
0.1V
±(1.5% reading + 2 digits)
1V
0.1mV
±(1.5% reading + 15 digits)
0.001V
±(1.2% reading + 3 digits)
0.01V
±(1.5% reading + 3 digits)
0.1V
1V
±(2.0% reading + 4 digits
±(1.0% reading + 3 digits)
0.1μA
1μA
±(1.5% reading + 3 digits)
0.01mA
0.1mA
0.01A
±(2.5% reading + 5 digits)
±(1.5% reading + 5 digits)
0.1μA
1μA
±(1.8% reading + 5 digits)
0.01mA
0.1mA
0.01A
±(3.0% reading + 7 digits)
±(1.2% reading + 4 digits)
0.1Ω
±(1.0% reading + 2 digits)
0.01kΩ
±(1.2% reading + 2 digits)
0.1kΩ
0.001MΩ
±(2.0% reading + 3 digits)
0.01MΩ
±(5.0% reading + 30 digits)
0.01nF
0.1nF
±(3.0% reading + 5 digits)
0.001μF
0.01μF
±(5.0% reading + 5 digits)
0.1μF
0.1%
±(1.2% reading + 2 digits)
±(3.0% reading + 9°F/5°C)
1°F
(probe accuracy not included)
1°C
12
MN16A V1.4 03/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MN16A and is the answer not in the manual?

Questions and answers