Failure
RX OPTIC FAIL
POWER MOD FAIL*
RXA BOARD FAIL*
RX Zn # BAL FAIL
RXB Zn # BAL FAIL
RXA Zn # PK FAIL*
RXB Zn # PK FAIL*
CABLE MISCONNECT*
* Critical Failure
© 2008 Garrett Metal Detectors
PD 6500i User MANUAL
Possible Failures and remedies
Verify and / or Replace
1. Make sure panel cables and PC
board are plugged in
2. IR Detector board assembly in
Panel B
Power Module
40-pin cable connection from Board
to Board
1. Cable and connector to Panel A
2. Circuit Board Connects
(# = zone with balance failure)
1. Cable and connector to Panel B
2. Circuit Board Connects
(# = zone with balance failure)
1. Panel A cable and connectors
2. Circuit Board Connections
1. Panel B cable and connectors
2. Circuit Board Connections
Ensure no blockage of IR
beam (of Panel A and Panel
B) at waist level of archway
Ensure line voltage is between
100 and 240 VAC
Check to see all connectors
are properly seated
Ensure no large, metal object
nearby. If necessary, move
object or relocate PD 6500i
Ensure no large, metal object
nearby. If necessary, move
object or relocate PD 6500i
Ensure no TX A or B FAIL.
Ensure no large, metal object
nearby. If necessary, move
object or relocate PD 6500i
Ensure no TX A or B FAIL.
Ensure no large, metal object
nearby. If necessary, move
object or relocate PD 6500i
Ensure that the cables are
attached to the circuit boards
are connected as described in
the inside cover of the
controller module.