Daikin BRC7EA63W Operation Manual
Daikin BRC7EA63W Operation Manual

Daikin BRC7EA63W Operation Manual

Wireless remote controller kit

Advertisement

Wireless Remote Controller Kit
MODELS
BRC7E63W
BRC7E66
BRC7EA63W
BRC7EA66
Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air
conditioner. It will tell you how to use the unit properly and
help you if any trouble occurs. After reading the manual, file
it away for future reference.

OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Daikin BRC7EA63W

  • Page 1: Operation Manual

    BRC7E66 BRC7EA63W BRC7EA66 Thank you for purchasing this Daikin air conditioner. Carefully read this operation manual before using the air conditioner. It will tell you how to use the unit properly and help you if any trouble occurs. After reading the manual, file...
  • Page 2: Table Of Contents

    PRIOR TO USE This operation manual is exclusively for instructions on how to use the wireless remote controller. Read also the operation manual attached to the indoor unit and to the outdoor unit for safe usage of the system and maintenance. The air conditioner corresponding to this controller comes under the term “appliances accessible to the general public”.
  • Page 3 ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH 21 20...
  • Page 4: Safety Precautions

    Consult your local dealer regarding 1. SAFETY PRECAUTIONS modification, repair and maintenance of the air conditioner or the remote To gain full advantage of the air conditioner’s controller. Improper workmanship may result in functions and to avoid malfunction due to water leakage, electric shocks or fire haz- mishandling, we recommend that you read ards.
  • Page 5 Be sure to use fuses with the correct Be sure to use a dedicated power sup- ampere reading. ply for the air conditioner. Do not use improper fuses, copper or The use of any other power supply may other wires as a substitute, as this may cause heat generation, fire, or product result in electric shock, fire, injury or dam- failures.
  • Page 6 Do not place heaters directly below Children should be supervised to the unit, as resulting heat can cause ensure that they do not play with the deformation. unit or its remote controller. Accidental operation by a child may result Do not allow a child to mount on the in impairment of bodily functions and outdoor unit or avoid placing any harm health.
  • Page 7: Names And Functions Of The Operating Section

    TEMPERATURE SETTING BUTTON 2. NAMES AND FUNCTIONS Use this button for SETTING TEMPER- OF THE OPERATING SEC- ATURE (Operates with the front cover TION (Fig. 1, 2) of the remote controller closed.) PROGRAMMING TIMER BUTTON DISPLAY “ ” (SIGNAL Use this button for programming TRANSMISSION) “START and/or STOP”...
  • Page 8: Handling For Wireless Remote Controller

    AIR FILTER CLEANING TIME 3. HANDLING FOR INDICATOR LAMP (Red) WIRELESS REMOTE Lights up when it is time to clean the air CONTROLLER filter. DEFROST LAMP (Orange) Precautions in handling remote con- Lights up when the defrosting opera- troller tion has started. (For straight cooling Direct the transmitting part of the remote type this lamp does not turn on.) controller to the receiving part of the air...
  • Page 9: Operation Procedure

    Pull it upward If the indoor unit is under centralized control, it is necessary to switch the remote controller’s setting. In this case, contact your DAIKIN dealer. 4. OPERATION PROCEDURE Refer to figure 1 on page [2] Remote • Operating procedure varies with heat controller pump type and cooling only type.
  • Page 10 〈〈FOR SYSTEMS WITHOUT COOL/ 〈〈FOR SYSTEMS WITH COOL/HEAT HEAT CHANGEOVER REMOTE CHANGEOVER REMOTE CONTROL CONTROL SWITCH〉〉 SWITCH〉〉 Refer to figure 1-1, 2 on page [2] Refer to figure 1-1,3 on page [2] OPERATION MODE OPERATION MODE SELECTOR SELECTOR Press OPERATION MODE SELECTOR (1) Select OPERATION MODE with the button several times and select the COOL/HEAT CHANGEOVER REMOTE...
  • Page 11 [EXPLANATION OF HEATING OPERA- In case of automatic operation TION] Each time this button is pressed, DEFROST OPERATION setting temperature shifts to “H” side. • As the frost on the coil of an outdoor unit increase, heating effect decreases and the Each time this button is pressed, setting temperature shifts to “L”...
  • Page 12 A. UP AND DOWN DIRECTION NOTE • The movable limit of the flap is change- • If you try cooling or programmed drying, able. Contact your Daikin dealer for while the flaps are facing downward, air details. flow direction may change unexpectedly.
  • Page 13: Down

    HOW TO SET MASTER PROGRAMMING TIME REMOTE CONTROLLER (For VRV system) Press the PROGRAMMING TIME but- ton and set the time for stopping or • When the system is installed as shown starting the system. below, it is necessary to designate the master remote controller.
  • Page 14 When the indoor unit with master remote EMERGENCY OPERATION controller is set to “COOL”, you can switch over operation mode between “FAN”, “DRY” When the remote controller does not work and “COOL”. due to battery failure or the absence thereof, When the indoor unit with master remote use this switch which is located beside the controller is set to “HEAT”, you can switch...
  • Page 15: Not Malfunction Of The Air Conditioner

    NOTE • Contact your Daikin dealer in case of changing the combination or setting of 6. HOW TO DIAGNOSE group control and two remote controller control systems.
  • Page 16: Mode

    Press PROGRAMMING TIMER BUT- Press PROGRAMMING TIMER BUT- TON and change the unit number. TON and change the malfunction code. Press to change the unit number until the Press until the indoor unit makes a long indoor unit beeps and perform the following beep.
  • Page 17: Swing

    [Trouble] The RUN lamp of the indoor unit is flashing and the unit does not work at all. Malfunction Code Unit No. which sensed trouble ON OFF TEMP TIME Number CODE DOWN RESERVE CANCEL UNIT N Operate the indoor unit with the remote con- TIMER troller of the same number.
  • Page 18 3P107422-8S EM00A046B (0807) HT...

This manual is also suitable for:

Brc7ea66

Table of Contents