Download Print this page
Daikin BRC7EA628 Operation Manual

Daikin BRC7EA628 Operation Manual

Wireless remote controller kit
Hide thumbs Also See for BRC7EA628:

Advertisement

Quick Links

OPERATION MANUAL
Wireless Remote Controller Kit
MODELS
BRC7EA628
BRC7EA629
BRC7EA630

Advertisement

loading

Summary of Contents for Daikin BRC7EA628

  • Page 1 OPERATION MANUAL Wireless Remote Controller Kit MODELS BRC7EA628 BRC7EA629 BRC7EA630...
  • Page 2 ON OFF H M L BRC7EA628, DOWN BRC7EA629: ON OFF BRC7EA630: TEMP TIME BRC7EA628, H M L BRC7EA629: DOWN BRC7EA630: RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH...
  • Page 3: Table Of Contents

    Thank you for purchasing this Daikin optional warm can be harmful to your physical accessory. Carefully read this operation man- condition and health.
  • Page 4 Consult your local dealer regarding Do not use the product in the atmo- what to do in case of refrigerant leakage. sphere contaminated with oil vapor, When the air conditioner is to be installed such as cooking oil or machine oil in a small room, it is necessary to take vapor.
  • Page 5 Do not place flammable sprays or Arrange the drain to ensure complete operate spray containers near the unit drainage. as this may result in fire. If proper drainage from the outdoor drain pipe does not occur during air conditioner Before cleaning, be sure to stop unit operation, there could be a blockage due operation, turn the breaker off or to dirt and debris build-up in the pipe.
  • Page 6 Press this button to select the fan speed, High-place work is required, to which utmost attention must be paid. HIGH/LOW (BRC7EA628/29) or HIGH/ If the scaffold is unstable, you may fall or MEDIUM/LOW (BRC7EA630) of your choice. topple down, thus causing injury.
  • Page 7: Handling Of Wireless Remote Controller

    RECEIVER 3. Handling of wireless This receives the signals from the remote controller remote controller. Precautions in handling remote con- OPERATING INDICATOR LAMP (Red) troller This lamp stays lit while the air Direct the transmitting part of the remote conditioner runs. It flashes when the controller to the receiving part of the air unit is in trouble.
  • Page 8: Operation Range

    Slide from above Pull it upward In this case, contact your DAIKIN dealer. 4. Operation range VRV System See the operation manual provided with the air conditioner. 5. Operation procedure Refer to figure 1 on page [1] •...
  • Page 9 OPERATION MODE of your choice as ■ HEATING OPERATION ..... “ ” follows. ■ COOLING OPERATION ....“ ” ■ FAN OPERATION ...... “ ” ■ HEATING OPERATION ....“ ” ■ AUTOMATIC OPERATION ....“ ” ■ DRY OPERATION ..... “ ”...
  • Page 10 Wait until High or Low fan speed can be selected the temperature in the room reach desired (BRC7EA628/29). temperature. High, Medium or Low fan speed can be • If hot air accumulates on the ceiling and feet selected (BRC7EA630).
  • Page 11 NOTE TIMER MODE • Stop flaps from swinging before trying to TIMER angle them. Working while the flaps are START/STOP moving may get your fingers pinched. Press the TIMER MODE START/STOP MOVEMENT OF THE AIR FLOW FLAP button several times and select the mode on the display.
  • Page 12 ■ For example. For Heat recovery system When one BS unit is connected with several When the timer is indoor units. programmed to stop ON OFF the system after TEMP TIME 3 hours and start the Outdoor unit system after DOWN 4 hours, the system BS unit...
  • Page 13: Not Malfunction Of The Air Conditioner

    [START] NOTE Press the emergency • Contact your Daikin dealer in case of operation switch. changing the combination or setting of group control and two remote controller The machine runs in the previous mode.
  • Page 14: How To Diagnose Trouble Spots

    Press PROGRAMMING TIMER BUT- If the OPERATION lamp lights, the system TON and change the unit number. is in normal condition. It does not restart immediately because a safety device operates to prevent overload of the sys- Press to change the unit number until the tem.
  • Page 15 MODE Reset of the display Press OPERATION MODE SELECTOR BUTTON to get the display back to the normal state. ON OFF Number TEMP TIME CODE Number DOWN RESERVE CANCEL UNIT N TIMER MODE SWING Operate the indoor unit with the remote con- troller of the same number.
  • Page 16: Disposal Requirements

    [Trouble] 8. Disposal requirements The RUN lamp of the indoor unit is flashing Your product and the batteries and the unit does not work at all. supplied with the controller are marked with this symbol. This Malfunction Code symbol means that electrical Unit No.
  • Page 20 3P505118-2B 2020.10...

This manual is also suitable for:

Brc7ea629Brc7ea630