1. Lay unit on its side and bolt locking casters or legs, to
the control side of unit.
2. Using the bolts provided for the non-locking casters, or
legs, bolt both the stacking spacer (provided in the kit)
and the non-locking caster, or legs, to the front side of the
unit. The stacking spacer should extend out the front of
the unit about three inches.
3. Carefully lift the rotisserie and place it on top of the
display, or bottom rotisserie, with the controls on the
same side.
Take care when moving the unit to prevent personal
injury. The SCR-8 weighs approximately 500 lbs.
(230 kg) and the SCR-6 weighs 380 lbs. (172 kg).
4. Remove the control side, side panels from both units.
5. Route the power cord inside of the SCD as shown in
Figure 1.
6. Thread the SCD power cord up through both units, using the
hole in the center, top of the SCD. See figure 2.
7. Using a flat-head screwdriver, mount the power cord wires to
the contactor terminals shown in figure 3.
8. Replace side panels, mounting the stacking brackets to each
side of the units, as shown in Figure 1 (page 2-3), using the
screws removed in step 4.
9. Unit is now ready for use.