Mechanical System
Evaporator disassembly
1. Press CLEAN button to purge evaporator. Turn
power OFF when LO WATER lights.
2. Unscrew and disconnect transport tube from
louvered docking assembly.
3. Unplug gear motor.
4. Remove shuttle housing:
§ Remove vent tube (Fig. 14.1).
§ Disconnect shuttle housing switch connections
(Fig. 14.2).
§ Remove two screws and lift shuttle housing (Fig. 14.3).
§ Remove stream divider (Fig. 14.4).
Fig. 12
Fig. 13
Fig. 14
3
4
18
2
1