MANUALLY
INITIATED
ELECTRONIC
DIAGNOSTICS
1. To enter diagnostics,
press the SELECT button
and
hold for three seconds.
The display
will change
to
show turbine
count, valve cycle position,
and position
switch status (open or closed).
• SALT
SIGNAL
s_rv
8
RECHARGE
7
6
5
-,,4
-'.-
FI FI Ft
--3
I
W-_ W -_ W-_ _"
2
=;_,_=
FLOW RATE
_--Z2!--
-...---- Valve Position Indicator
Number
of Days since
the last Regeneration
_....._ Turbine Count
(No Water
Flowing)
Position Switch Indicator
(Open)
Figure 41
TURBINE
OPERATION:
If no water
is flowing
through
the softener, the turbine
indicator
displays
three zeros.
When water
is flowing,
a 000 to 140 count repeats for
each gallon
of water
passing through
the turbine.
To
check for positive
operation
of the turbine
if zeros are
shown, open a nearby
soft water
faucet
and observe
the turbine
count.
If you don't get a reading
in the dis-
play with faucet open, pull the sensor housing from the
valve outlet
port (see Fig. 43).
Pass a small magnet
back and forth in front of the sensor.
You should get a
reading
in the display.
If you get a reading,
unhook the
inlet and outlet plumbing
and check the turbine
for
binding.
POSITION
SWITCH
STATUS: With
the valve in service,
or any of the recharge
cycle positions,
the position
switch indicator
will show the switch open.
While
the
valve is rotating
from one position
to another,
the posi-
tion switch indicator
will show the switch closed.
There
is likely a problem
if indications
vary from this pattern.
SALT
SIGNAL
LEVEL LEVEL
8
7
6
5
_4
_3
m_ 2 _,,.::
Z!. J Ft _
_"
3'wi U
TIME REMAINING
-'- ,78-
Minutes of Cycle (ex-
ample:
Fill) Remaining
Turbine Count
(Water
Flowing)
Figure 42
OTHER INFORMATION:
While
in the diagnostics
screen, the following
information
is available
and may
be beneficial
for various reasons.
This information
is
retained
by the electronic
controller
from the first time
electrical
power is applied
to the unit.
Press and hold the /X UP button
to display
the num-
ber of days this controller
has had electrical
power
applied.
t
Motor
U
Position /
Sensor
Switch
Housing
l_
Turbine
Turbine
Support
& Shaft
Valve Outlet
Figure
43
Press and hold the V
DOWN
button to display
the
number
of regenerations
initiated
by this controller
since the model code number was entered.
NOTE: If the electronic
controller
is left in the diagnos-
tic display
(or a flashing
display
when setting
times or hardness), the normal
time of day dis-
play automatically
returns if a button has not
been pressed for 4 minutes.
To return to the
diagnostic
display,
repeat step 1, above.
RESETTING
TO FACTORY
DEFAULTS:
To reset the electronic
controller
to its factory
default
for all settings
(time, hardness, etc.):
1. Press the SELECT button
and hold it until the display
changes
twice to show the flashing
model code.
2. Press the /X UP button to display
a flashing
"SOS".
SALT
SIGNAL
LEVEL
LEVEL
8
7
6
5
4
3
2
1
SALT
SIGNAL
LEVEL LEVEL
8
7
5
5
4
3
2
t
Figure
44
3. Press the SELECT button,
and the electronic
controller
will restart.
4. Set the present time, hardness, etc., as described
on
pages 12 & 13.