Install Single Bypass Valve; Install Holding Clips; Alternate Bypass Valve Installation; Assemble Inlet And Outlet Plumbing - Kenmore 625.385200 Use & Care Manual

Hybrid water softener
Hide thumbs Also See for 625.385200:
Table of Contents

Advertisement

Available languages

Available languages

INSTALL SINGLE
BYPASS VALVE (cont.)
Before installing the bypass valve and/or
installation
adaptors,
make sure that the turbine
and support
are
firmly
in place inside the softener
valve's outlet port.
Turbine
Support
Valve
Outlet j
Turbine /
Figure 7
INSTALL
HOLDING
CLIPS
Bypass Valve or
Installation
Adaptor
\
Plastic Clip
Valve Inlet or Outlet
O-Ring
Plastic clip snaps
into groove
in
bypass or adaptor
Figure 8
ALTERNATE
BYPASS VALVE
INSTALLATION
If connecting
to floor
level plumbing,
install
the bypass valve turned
downward,
as shown.
OUT
iN
Figure 9
ASSEMBLE
INLET AND
OUTLET
PLUMBING
Measure,
cut (thread
if needed)
and put together
all
pipe and fittings
up to the main water
pipe.
Make
sure
that the incoming
water
supply
pipe goes to the valve
inlet side.
CAUTION:
Never solder fittings
while connected
to
nonmetallic
parts.
Wait
until soldered
pipe
has cooled
before connection.
See Fig. 10.
CAUTION:
Be careful
when putting
pipe fittings
togeth-
er.
Do not cross thread,
and do not over-
tighten.
______
/Vlain Water
Pipe
Incoming
_
_
Hard
4. Solder.
_
Water
NOTE: To be certain
that heat will not
1. Cut pipe to
travel
down the pipe
correct
length
and into the bypass
valve or installation
adaptors,
wrap the
2. Solder. When
bottom
of the pip_
/
cool, do step 3.
and the bypass v_lve
with a wet rag. L_
__
-_
3. Put threaded
J
port.
adaptor
into
bypass valve
Figure 10
Questions?
Call the Kenmore
Water
Line 1-800-426-9345
or visit www.kenmorewater.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite 625.385200

Table of Contents