SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
AUTOMATIC
ELECTRONIC
DIAGNOSTICS
The faceplate
timer
(PWA)
com-
puter
has a self-diagnostic
func-
tion for the electrical
system,
ex-
EFr
0
cept
for input
power
and
water
meter.
The computer
monitors
electronic
compo-
nents and circuits
for correct operation.
Ifa malfunc-
tion occurs,
an error
code appears
in the faceplate
display.
CODE
Err1, Err3,
Err4
Err5
The chart
below
shows
the error
codes
that
could
appear,
and the possible
defects
for each code.
While
an error code appears
in the display,
all face
plate buttons
are inoperable
except
the SELECT but-
ton. SELECT remains
operational
so the service
per-
son
can
make
the MANUAL
INITIATED
ELEC-
TRONIC
DIAGNOSTICS
(below)
to further
isolate
the defect,
and check the water
meter.
POSSIBLE DEFECT
MOST LIKELY
_..--"
]D,. LESS LIKELY
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
hiqh torque
faceplate timer (PWA)
PROCEDURE
FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug
transformer
from outlet 2. Correct
defect
3. Plug in transformer
4. Wait for 6 minutes.
The error code will return if the defect was not corrected.
MANUAL
INITIATED
ELECTRONICS
DIAGNOSTICS
To
the SELECT
button
enter
diagnostics,
press
until
000 - - shows
in the display.
I-I £'1 I_
]
!,.JU U - -
A. The first 3 digits indicate
water
meter
operation
as follows:
000 (steady) =
Soft water
not in use, and no
flow through
the meter.
--OPEN
A NEARBY SOFT WATER FAUCET--
000 to 199 (continual)
= Repeats
display
for each
gallon
of water
passing
through
the meter.
If you don't
get a reading
in the display
with faucet
open,
pull
the sensor
from
the valve
outlet
port.
Pass a small
magnet
back
and forth
in front
of the
sensor.
You should
get a reading
in the display.
If
you get a reading,
unhook
the in and out plumbing
and check
the turbine
for binding.
POSITION
SWITCH
VALVE
OU
SENSOR
RBINE
lINE
SUPPORT AND
SHAFT
The letter
(P) and
dashes
indicate
POSITION
switch
operation.
If the
letter
appears,
the
switch
is closed.
If the dashes
show,
the switch
is open.
Use
the RECHARGE
button
to manually
ad-
vance the valve into each cycle and check correct
switch
operation.
5-2
Problems,
Questions?
Call
1-800-426-9345