E. Junction Box Installation
• Remove the screw attaching the junction box/re-
ceptacle to the outer shell, rotate the junction box
inward to disengage it from the outer shell (see
Figure 10.4).
• Pull the electrical wires from outside the appli-
ance through this opening into the valve compart-
ment.
• Feed the necessary length of wire through the
connector.
• Make all necessary wire connections to the junc-
tion box/receptacle and reassemble the junction
box/receptacle to the outer shell.
F. Wall Switch Installation for Fan (Optional)
If the box is being wired to a wall
mounted switch for use with a fan (See
Figure 10.5):
• The power supply for the appliance
must be brought into a switch box.
• The power can then be supplied from
the switch box to the appliance using
a minimum of 14-3 with ground wire.
• At the switch box connect the black
(hot) wire and red (switch leg) wire to
the wall switch as shown.
• At the appliance connect the black
(hot), white (neutral) and green
(ground) wires to the junction box as
shown.
• Add a 1/4 inch insulated female con-
nector to the red (switch leg) wire,
route it through the knockout in the
face of the junction box, and connect
to the top fan switch connector (1/4
inch male) as shown.
40
Figure 10.4 Junction Box Detail
JUNCTION BOX
Figure 10.5 Junction Box Wired to Wall Switch
Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08
GRN wire
inside box
MINIMUM 14-3
A W G
WITH GROUND
Red
Black
White
Green
Red
Romex
Connector
14/2WG
Copper
ground attached
to GRN screw with
GRN wire
Note: Do NOT wire 110
VAC to wall switch.
SWITCH
Black
White
Green
POWER
SUPP LY WIRE S