Standing Pilot Ignition System Wiring - Heat & Glo 6000G Owner's Manual

Heat & glo lifestyle air conditioner user manual
Hide thumbs Also See for 6000G:
Table of Contents

Advertisement

PLUG-IN
3V TRANSFORMER
ON/OFF
WALL SWITCH
IGNITION
MODULE
(3V)
VALVE
NEUTRAL
BLACK WIRE CAN BE
PLUGGED INTO ANY
OF #1 - #5 LOCATIONS
ON THE HOT SIDE
WHITE WIRE CAN BE
PLUGGED INTO ANY
OF#1 - #5 LOCATIONS
ON THE NEUTRAL SIDE
Figure 10.2
Intellifi re Pilot Ignition (IPI) Wiring Diagram
D. Standing Pilot Ignition System Wiring
• This standing pilot ignition system wiring does not
require a 110 VAC supply to operate.
• It is recommended that a 110 VAC junction box be
installed for use with a fan or remote control. (See Figure
10.4 for junction box wiring).
S TA N D IN G
P IL O T
W H T
R E D
Figure 10.3 Standing Pilot Ignition Wiring Diagram
LOW VOLTAGE
SEE NOTE 1
GROUND
REMOTE
CONTROL
HOT
TRANSFORMER
3 VAC
PLUG-IN
B R N
R E D
VA LV E
O N /O F F P IG G Y B A C K
W IR E
Heat & Glo • 6000G, 6000G-IPI • 2103-900 Rev. M • 9/08
IGNITION MODULE 3 VAC
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS*
ORG
BLK
RED
VALVE
REMOTE
JUMPER WIRE
*Note: Appliance will not operate unless properly grounded.
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
INTERMITTENT
PILOT IGNITOR
THERMOSTAT
WIRE
ASSEMBLY
CAUTION
WARNING
Shock hazard.
• Replace damaged wire with type 105º C rated
wire.
• Wire must have high temperature insulation.
T H E R M O S TAT
W IR E A S S E M B LY
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000g-ipi6000g-ipilp6000g-lp

Table of Contents