TROUBLESHOOTING (cont.)
PROBLEM
Equipment will not operate
Brew cycle will not start
Automatic refill will not operate
after drawing hot water.
PROBABLE CAUSE
1. No power or incorrect voltage
1. No water
2. Water strainer/Flow Control
3. On/Left switch
4. Start switch
5. Brew timer
6. Relay
7. Solenoid valve
1. On/Left switch
Page 8
REMEDY
(A) Plug in brewer.
(B) Check wall outlet for 120V ac
(C) Check circuit breaker/fuse.
Check plumbing and shut-off
valves.
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/Flow con-
trol and check for obstructions.
Clear or replace.
Refer to Service - On/Left switch
for testing procedures. See page
22.
Refer to Service - Start switch for
testing procedures. See page 26.
Refer to Service - Brew timer for
testing procedures. See page 16.
Refer to Service - Relay for testing
procedures. See page 23.
Refer to Service - Solenoid valve
for testing procedures. See page
25.
(A) The On/Left switch must be
in the upper position for the au-
tomatic refill to operate.
(B) Refer to Service - On/Left
switch for testing procedures. See
page 22.
10179 060100