Advertisement

H. Mineral Wool
WARNING
Explosion Risk.
• Follow ember placement instructions in manual.
• Do NOT place embers directly over burner ports.
• Replace ember material annually.
Improperly placed embers interferes with proper burner
operation.
Place individual pieces of embers in front of and around the
gas log where they can be seen. Space them so that gas
can contact them on all sides. Avoid stacking the embers
on top of each other.
Figure 8.22
Note: Do not block gas ports.
20
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev. H • 10/08
I. Blower Installation
Included in kit: Blower.
Tools required: Powered Phillips head screwdriver.
Turn off gas and disconnect appliance from electricity.
Remove logs and burner from appliance. Remove blower
access cover in bottom of firebox by removing the screws.
Retain screws for reassembly.
Figure 8.23
Disconnect wires from the snap disk on back of access
cover.
Figure 8.24
Lift blower off of studs and pull through opening.
Figure 8.25

Advertisement