Quadra-Fire Vented Gas Fireplace Heater COLBAY-INS Owner's Manual & Installation page 2

Direct vent gas appliance
Table of Contents

Advertisement

Hearth & Home Technologies welcomes you to our tradi-
tion of excellence! In choosing a Quadra-Fire appliance,
you have our assurance of commitment to quality, durabil-
ity, and performance.
This commitment begins with our research of the market,
including 'Voice of the Customer' contacts, ensuring we
make products that will satisfy your needs. Our Research
and Development facility then employs the world's most
advanced technology to achieve the optimum operation of
our stoves, inserts and fi replaces. And yet we are old-fash-
ioned when it comes to craftsmanship. Each appliance
LOCATION: HANGING ON A CHAIN ON BACK OF APPLIANCE
Test Lab &
Report No.
2
and Welcome to the Quadra-Fire Family
SAMPLE OF SERIAL NUMBER / SAFETY LABEL
SERIAL
Tested and
Beaverton
NO.
Listed by
Oregon USA
C
OMNI- Test Laboratories, Inc.
Report No. / Rapport Numero
061-S-63-5
NOT FOR USE WITH SOLID FUEL
FAN TYPE VENTED CIRCULATOR Blower Electrical Rating115 V., 1.5 Amps, 60 Hz, 150 Watts
P.4.1-02 Canada Minimum Pipe 69% NG / 71% LP
APPROVED FOR CANADA AND USA TO:
ANSI Z21.88b-2003 / CSA 2.33b-2003 Vented Gas Fireplace Heate r, and applicable sections of UL307b Gas Burning
Heating Appliances for Manufactured Homes and Recreational Vehicles, CAN/CG A 2.17-M91 "Gas Fired Appliances
for use at High Altitudes."
This appliance is manufactured for operation with Natural Gas. For conversion to propane the Manufacturer's kit
provided with the stove must be used in conjuntion with the instructions in the owner's manual.
This vented gas fireplace heater is not for use with air filters.
This appliance may be installed in a bedroom or bedsitting room; in Canada remote thermostat installation is
required.
For use with Natural Gas
Input Rate on "HI" (BTU/Hr)
Input Rate on "LO" (BTU/Hr)
Main Burner Orifice (DMS)
Minimum Inlet Pressure (Inches W.C.)
Maximum Inlet Pressure (Inches W.C.)
Manifold Pressure on "HI" (Inches W.C.)
Efficiency up to
AFUE
This appliance equipped for altitudes 0-2000' (0-610m) in USA; and in Canada for altitudes of 0-4500' (0-1370m). In USA for
Altitudes above 2000', the vent configuration, orifice, or combination of both may need to be changed. See Owner's Manual for
information on making these changes.
This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if
none, follow The National Fuel Gas Code,ANSI Z223.1 and NFPA 54; or Canadian Installation Codes CAN/CGA-B149.
NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or
licensed as required by the locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed
plumber or gas fitter.)
MINIMUM CLEARANCES TO COMBUSTIBLES
Manufactured by:
Date of Manufacture / Date du Manufacturier
2005
2006
2007
Jan
Feb
Mar
Quadra-Fire • Columbia Bay Insert • 7002-109 Rev. H • 10/08
is meticulously fabricated and gold and nickel surfaces
are hand-fi nished for lasting beauty and enjoyment. Our
pledge to quality is completed as each model undergoes
a quality control inspection.
to shipping: Our guarantee of quality is more than a word,
it's Quadra-Fire tradition, and we proudly back this tradition
with a Limited Lifetime Warranty.
We wish you and your family many years of enjoyment in
the warmth and comfort of your hearth appliance. Thank
you for choosing Quadra-Fire.
XXX
MODEL: XXXXXXX
VENTED GAS APPLIANCE
For use with Propane
"0-2000'
"0-2000'
30,000
28,000
22,500
22,650
36
52
4.5"
11"
7.0"
14"
3.5"
10"
82.5%
81%
71%
72.5%
DO NOT REMOVE THIS LABE L
Apr
May
Jun
Jul
Aug
Sep
Oct
!
From design, to fabrication,
Serial Number
R
Model Name
MADE IN U.S.A.
Manufactured
Nov
Dec
Date
7031-221

Advertisement

Table of Contents
loading

This manual is also suitable for:

Colbay-ins

Table of Contents