Mantel And Wall Projections - Heat & Glo SL-750TRSFHHIPI Owner's Manual

Hearth and home technologies gas fireplace installation & operating manual
Table of Contents

Advertisement

B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing closer than the minimums list-
ed must be constructed entirely of noncombustible materi-
als (i.e., steel studs, concrete board, etc.) Failure to comply
could cause fi re.
All measurements are in inches.
7
6
5
4
3
4
TOP OF HOOD OR FIREPLACE OPENING
Figure 13.12 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
TOP VIEW
2-7/8 IN.
MINIMUM
Note: Clearance from fi replace
opening to perpendicular wall.
Figure 13.13 Mantel Leg (Acceptable on both sides of opening)
CEILING
12
11
10
9
8
32
13
12
11
10
9
8
7
6
5
1/2 IN.
MINIMUM
3 FT. MAXIMUM
Heat & Glo • SL-750TRSFHHIPI • 2156-900 Rev. F • 11/08
TOP VIEW
5-3/8 IN.
MINIMUM
Note: Clearance from fi replace
opening to perpendicular wall.
Figure 13.14 Wall Projection (Acceptable on one side of opening)
3-1/2 in.
1/2 in.
NON-COMBUSTIBLE ZONE
Figure 13.15 Non-Combustible Zone
3 IN.
MINIMUM
UNLIMITED
1/2 in.
SHEETROCK
NON-COMBUSTIBLE
BOARD SHIPPED
WITH APPLIANCE